Transcranial Doppler ultrasound to assess cerebrovascular reactivity: reliability, reproducibility and effect of posture
Open Access
Abstract
Transcranial Doppler ultrasound (TCD) allows measurement of blood flow velocities in the intracranial vessels, and can be used to assess cerebral vasodilator responses to a hypercapnic stimulus. The reliability of this technique has not been established, nor is there agreement about whether the technique should be performed in sitting or lying postures. We tested the intra- and inter-rater reliability of measures of cerebrovascular reactivity (CVR) in 10 healthy adults, in sitting and lying postures. Participants underwent triplicate bilateral ultrasound assessment of flow velocities in the middle cerebral arteries whilst sitting and lying supine prior to and during inhalation of Carbogen (5% CO2, 95% O2) for 2 min. This procedure was performed twice by each of two raters for a total of four sessions. CVR was calculated as the difference between baseline and the peak blood flow velocity attained during CO2 inhalation. Intraclass correlation coefficients (ICCs) for intra-rater reliability were greater sitting than lying for both raters (e.g. Rater 1 ICC sitting = 0.822, lying = 0.734), and inter-rater reliability was also greater in sitting (e.g. sitting ICC = 0.504, lying = 0.081). These results suggest that assessment of CVR using TCD should be performed with participants sitting in order to maximise CVR measurement reliability.Keywords
This publication has 31 references indexed in Scilit:
- Transcranial Perfusion Sonography Using a Low Mechanical Index and Pulse Inversion Harmonic Imaging: Reliability, Inter-/Intraobserver VariabilityUltraschall in der Medizin - European Journal of Ultrasound, 2010
- Reliability of dynamic cerebral autoregulation measurement using spontaneous fluctuations in blood pressureClinical Science, 2009
- Relationships of transcranial blood flow Doppler parameters with major vascular risk factors: TCD study in patients with a recent TIA or nondisabling ischemic strokeJournal of Clinical Ultrasound, 2006
- Regional Impairment of Cerebrovascular Reactivity and BOLD Signal in Adults After StrokeStroke, 2005
- The Stroke Prognosis Instrument II (SPI-II)Stroke, 2000
- Cerebrovascular Reactivity Evaluated by Transcranial Doppler: Reproducibility of Different MethodsCerebrovascular Diseases, 1999
- The Variability of Cerebrovascular Reactivity with Posture and TimeJournal of Neurosurgical Anesthesiology, 1996
- Cerebral Vasoreactivity Assessed With Transcranial Doppler and Regional Cerebral Blood Flow MeasurementsStroke, 1995
- Comparison of flow and velocity during dynamic autoregulation testing in humans.Stroke, 1994
- Transcranial Doppler–Techniques, Application, and InstrumentationNeurosurgery, 1993