Optimizing Antimony Speciation Analysis via Frontal Chromatography–ICP-MS to Explore the Release of PET Additives
Open Access
Abstract
Antimony (Sb) contamination poses significant environmental and health concerns due to its toxic nature and widespread presence, largely from anthropogenic activities. This study addresses the urgent need for an accurate speciation analysis of Sb, particularly in water sources, emphasizing its migration from polyethylene terephthalate (PET) plastic materials. Current methodologies primarily focus on total Sb content, leaving a critical knowledge gap for its speciation. Here, we present a novel analytical approach utilizing frontal chromatography coupled with inductively coupled plasma mass spectrometry (FC-ICP-MS) for the rapid speciation analysis of Sb(III) and Sb(V) in water. Systematic optimization of the FC-ICP-MS method was achieved through multivariate data analysis, resulting in a remarkably short analysis time of 150 s with a limit of detection below 1 ng kg−1. The optimized method was then applied to characterize PET leaching, revealing a marked effect of the plastic aging and manufacturing process not only on the total amount of Sb released but also on the nature of leached Sb species. This evidence demonstrates the effectiveness of the FC-ICP-MS approach in addressing such an environmental concern, benchmarking a new standard for Sb speciation analysis in consideration of its simplicity, cost effectiveness, greenness, and broad applicability in environmental and health monitoring.Keywords
This publication has 54 references indexed in Scilit:
- Selective organomercury determination by ICP-MS made easyAnalytica Chimica Acta, 2022
- Antimony contamination and its risk management in complex environmental settings: A reviewEnvironment International, 2022
- Antimony, a pollutant of emerging concern: A review on industrial sources and remediation technologiesChemosphere, 2021
- Antimony and PET bottles: Checking factsChemosphere, 2020
- Spatial and temporal variability of metal(loid)s concentration as well as simultaneous determination of five arsenic and antimony species using HPLC-ICP-MS technique in the study of water and bottom sediments of the shallow, lowland, dam reservoir in PolandEnvironmental Science and Pollution Research, 2020
- Determination of antimony compounds in waters and juices using ion chromatography-inductively coupled plasma mass spectrometryFood Chemistry, 2017
- Antimony Assessment in PET Bottles for Soft DrinkFood Analytical Methods, 2017
- Determination of traces of Sb(III) using ASV in Sb-rich water samples affected by miningAnalytica Chimica Acta, 2015
- Migration of antimony from polyethylene terephthalate used in mineral water bottlesFood Chemistry, 2015
- Determination of antimony(III) and (V) in natural water by cathodic stripping voltammetry with in-situ plated bismuth film electrodeMicrochimica Acta, 2009