Autofocusing and Polar Body Detection in Automated Cell Manipulation
Authors:
- 13 July 2016
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 64 (5) , 1099-1105
Abstract
Autofocusing and feature detection are two essential processes for performing automated biological cell manipulation tasks. In this paper, we have introduced a technique capable of focusing on a holding pipette and a mammalian cell under a bright-field microscope automatically, and a technique that can detect and track the presence and orientation of the polar body of an oocyte that is rotated at the tip of a micropipette. Both algorithms were evaluated by using mouse oocytes. Experimental results show that both algorithms achieve very high success rates: 100% and 96%. As robust and accurate image processing methods, they can be widely applied to perform various automated biological cell manipulations.Keywords
Funding Information
- Singapore Polytechnic
- Nanyang Technological University
- Ministry of Education (MOE2013-TIF-2-G-014)
This publication has 27 references indexed in Scilit:
- Automated Vitrification of Embryos: A Robotics ApproachIEEE Robotics & Automation Magazine, 2015
- Robotic Cell Rotation Based on the Minimum Rotation ForceIEEE Transactions on Automation Science and Engineering, 2014
- Automatic Blastomere Recognition from a Single Embryo ImageComputational and Mathematical Methods in Medicine, 2014
- Three-Dimensional Rotation of Mouse EmbryosIEEE Transactions on Biomedical Engineering, 2012
- CONTENT-BASED AUTOFOCUSING IN AUTOMATED MICROSCOPYImage Analysis and Stereology, 2010
- Lighting-Aware Segmentation of Microscopy Images for In Vitro FertilizationLecture Notes in Computer Science, 2009
- Contact Detection in Microrobotic ManipulationThe International Journal of Robotics Research, 2007
- Robust autofocusing in microscopyCytometry, 2000
- Comparison of autofocus methods for automated microscopyCytometry, 1991
- A comparison of different focus functions for use in autofocus algorithmsCytometry, 1985