Comparison of six ECMO selection criteria and analysis of factors influencing their accuracy
Authors:
- 1 January 1991
- journal article
- research article
- Published by Wiley in Pediatric Pulmonology
- Vol. 11 (3) , 223-232
Abstract
This study compared six extracorporeal membrane oxygenation (ECMO) selection criteria in 42 neonates and analyzed factors influencing the accuracy of outcome predictions. The sensitivity of the criteria in identifying fatal cases varied from 0.44 to 0.94 and the specificity of predictions of survival ranged from 0.42 to 0.69. The criterion having the highest sensitivity had the lowest specificity and conversely the criterion with the lowest sensitivity had the highest specificity. Overall accuracy of the criteria, as measured by the total number of correct outcome predictions, differed little among the criteria (23/42 to 27/42 correct predictions). Three factors influenced predictive accuracy: 1) a primary diagnosis of congenital diaphragmatic hernia (CDH) was associated with a greater mortality (P < 0.001) and a significantly higher positive predictive value (PPV) for all criteria (P = 0.0009–0.012) than that seen in patients with other primary diagnoses; 2) calculating the alveolar‐arterial oxygen gradient using an assumed, rather than measured barometric pressure, or estimating oxygenation index using a calculated, rather than a measured, mean airway pressure, increased false positive mortality predictions in non‐CDH patients; and 3) requiring a peak inspiratory pressure (PIP) of at least 50 cm H2O in the definition of maximal medical management, rather than a PIP of 20–49 cm H2O, significantly increased the PPV for three of four criteria examined (P = 0.02–0.04). Awareness of these factors may facilitate the identification of neonates who need ECMO to survive.Keywords
This publication has 25 references indexed in Scilit:
- Aluminum-Containing Emboli in Infants Treated with Extracorporeal Membrane OxygenationNew England Journal of Medicine, 1988
- Ventilatory predictors of pulmonary hypoplasia in congenital diaphragmatic hernia, confirmed by morphologic assessmentThe Journal of Pediatrics, 1987
- Hemorrhagic complications during extracorporeal membrane oxygenation: Prevention and treatmentJournal of Pediatric Surgery, 1986
- Antecedents of Cerebral PalsyNew England Journal of Medicine, 1986
- Extracorporeal membrane oxygenation and congenital diaphragmatic hernia: Modification of the Pulmonary vasoactive profileJournal of Pediatric Surgery, 1985
- Alveolar-Arterial oxygen gradients versus the neonatal pulmonary insufficiency index for prediction of mortality in ECMO candidatesJournal of Pediatric Surgery, 1984
- Persistent pulmonary hypertension in the neonate: Diagnosis and managementThe Journal of Pediatrics, 1983
- Clinical use of an extracorporeal membrane oxygenator in neonatal pulmonary failureJournal of Pediatric Surgery, 1982
- The contribution of PDA in the neonate with severe RDSThe Journal of Pediatrics, 1980
- The effect of independent variations in inspiratory-expiratory ratio and end expiratory pressure during mechanical ventilation in hyaline membrane disease: The significance of mean airway pressureThe Journal of Pediatrics, 1977