Vacuum Ultraviolet Detector for Gas Chromatography
- 7 August 2014
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 86 (16) , 8329-8335
Abstract
Analytical performance characteristics of a new vacuum ultraviolet (VUV) detector for gas chromatography (GC) are reported. GC-VUV was applied to hydrocarbons, fixed gases, polyaromatic hydrocarbons, fatty acids, pesticides, drugs, and estrogens. Applications were chosen to feature the sensitivity and universal detection capabilities of the VUV detector, especially for cases where mass spectrometry performance has been limited. Virtually all chemical species absorb and have unique gas phase absorption cross sections in the approximately 120–240 nm wavelength range monitored. Spectra are presented, along with the ability to use software for deconvolution of overlapping signals. Some comparisons with experimental synchrotron data and computed theoretical spectra show good agreement, although more work is needed on appropriate computational methods to match the simultaneous broadband electronic and vibronic excitation initiated by the deuterium lamp. Quantitative analysis is governed by Beer–Lambert Law relationships. Mass on-column detection limits reported for representatives of different classes of analytes ranged from 15 (benzene) to 246 pg (water). Linear range measured at peak absorption for benzene was 3–4 orders of magnitude. Importantly, where absorption cross sections are known for analytes, the VUV detector is capable of absolute determination (without calibration) of the number of molecules present in the flow cell in the absence of chemical interferences. This study sets the stage for application of GC-VUV technology across a wide breadth of research areas.Keywords
This publication has 14 references indexed in Scilit:
- Ab Initio Calculation of UV-Vis Absorption Spectra of a Single Molecule Chlorophyll a: Comparison Study between RHF/CIS, TDDFT, and Semi-Empirical MethodsITB Journal of Sciences, 2012
- Qualitative Aspects in the Analysis of Pesticide Residues in Fruits and Vegetables Using Fast, Low-Pressure Gas Chromatography−Time-of-Flight Mass SpectrometryJournal of Agricultural and Food Chemistry, 2011
- Analysis of the Gas Phase of Cigarette Smoke by Gas Chromatography Coupled with UV-Diode Array DetectionAnalytical Chemistry, 2006
- Evaluation of common organic solvents for gas chromatographic analysis and stability of multiclass pesticide residuesJournal of Chromatography A, 2004
- Identification of compounds and specific functional groups in the wavelength region 168–330 nm using gas chromatography with UV detectionJournal of Chromatography A, 2000
- Polycyclic aromatic hydrocarbons (PAH)—Problems and progress in sampling, analysis and interpretationMarine Pollution Bulletin, 1994
- Gaussian basis sets for use in correlated molecular calculations. I. The atoms boron through neon and hydrogenThe Journal of Chemical Physics, 1989
- Capillary gas chromatographic analysis with the far-UV absorbance detectorJournal of Chromatography A, 1988
- Trace analysis of volatile polar organics by direct aqueous injection gas chromatographyChromatographia, 1987
- An intermediate neglect of differential overlap technique for spectroscopy: Pyrrole and the azinesTheoretical Chemistry Accounts, 1973