O2 uptake kinetics during exercise at peak O2 uptake
Authors:
- Barry W. ScheuermannBSBarry W. Scheuermann
- Thomas J. BarstowTBThomas J. Barstow
- 1 November 2003
- journal article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 95 (5) , 2014-2022
Abstract
Compared with moderate- and heavy-intensity exercise, the adjustment of O2 uptake (V̇o2) to exercise intensities that elicit peak V̇o2 has received relatively little attention. This study examined the V̇o2 response of 21 young, healthy subjects (25 ± 6 yr; mean ± SD) during cycle ergometer exercise to step transitions in work rate (WR) corresponding to 90, 100, and 110% of the peak WR achieved during a preliminary ramp protocol (15-30 W/min). Gas exchange was measured breath by breath and interpolated to 1-s values. V̇o2 kinetics were determined by use of a two- or three-component exponential model to isolate the time constant (τ2) as representative of V̇o2 kinetics and the amplitude (Amp) of the primary fast component independent of the appearance of any V̇o2 slow component. No difference in V̇o2 kinetics was observed between WRs (τ90 = 24.7 ± 9.0; τ100 = 22.8 ± 6.7; τ110 = 21.5 ± 9.2 s, where subscripts denote percent of peak WR; P > 0.05); nor in a subgroup of eight subjects was τ2 different from the value for moderate-intensity ( 0.05). As expected, the Amp increased with increasing WRs (Amp90 = 2,089 ± 548; Amp100 = 2,165 ± 517; Amp110 = 2,225 ± 559 ml/min; Amp90 vs. Amp110, P < 0.05). However, the gain (G) of the V̇o2 response (ΔV̇o2/ΔWR) decreased with increasing WRs (G90 = 8.5 ± 0.6; G100 = 7.9 ± 0.6; G110 = 7.3 ± 0.6 ml·min-1·W-1; P < 0.05). The Amp of the primary component approximated 85, 88, and 89% of peak V̇o2 during 90, 100, and 110% WR transitions, respectively. The results of the present study demonstrate that, compared with moderate- and heavy-intensity exercise, the gain of the V̇o2 response (as ΔV̇o2/ΔWR) is reduced for exercise transitions in the severe-intensity domain, but the approach to this gain is well described by a common time constant that is invariant across work intensities. The lower ΔV̇o2/ΔWR may be due to an insufficient adjustment of the cardiovascular and/or pulmonary systems that determine O2 delivery to the exercising muscles or due to recruitment of motor units with lower oxidative capacity, after the onset of exercise in the severe-intensity domain.Keywords
This publication has 44 references indexed in Scilit:
- ATP and heat production in human skeletal muscle during dynamic exercise: higher efficiency of anaerobic than aerobic ATP resynthesisThe Journal of Physiology, 2003
- Influence of peak &OV0312;O2 and muscle fiber type on the efficiency of moderate exerciseMedicine & Science in Sports & Exercise, 2002
- Muscle heat production and anaerobic energy turnover during repeated intense dynamic exercise in humansThe Journal of Physiology, 2001
- Influence of exercise intensity on the on‐ and off‐transient kinetics of pulmonary oxygen uptake in humansThe Journal of Physiology, 2001
- The slow component of O2uptake is not accompanied by changes in muscle EMG during repeated bouts of heavy exercise in humansThe Journal of Physiology, 2001
- Influence of muscle fibre type and fitness on the oxygen uptake/power output slope during incremental exercise in humansExperimental Physiology, 2000
- Influence of Muscle Fibre Type and Fitness on the Oxygen Uptake/Power Output Slope During Incremental Exercise in HumansExperimental Physiology, 2000
- Inferences from pulmonary O2 uptake with respect to intramuscular [phosphocreatine] kinetics during moderate exercise in humansThe Journal of Physiology, 1999
- A study of cardiorespiratory dynamics with step and ramp exercise tests in normoxia and hypoxiaCardiovascular Research, 1989
- The Ether Soluble Porphyrins Found in the Urine of Normal Man and RabbitScandinavian Journal of Clinical and Laboratory Investigation, 1962