Real‐timein vitrointravascular reconstruction and navigation for endovascular aortic stent grafting
Authors:
- 9 February 2016
- journal article
- research article
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 12 (4) , 648-657
Abstract
Background: Trans‐catheter endovascular stent grafting minimizes trauma and increases the benefitting patient population. However, the alignment between stent graft branches and vasculature branches remains time‐consuming and challenging, and such techniques require a significant amount of contrast agent for imaging.Methods: A new framework for intravascular reconstruction based on sensor fusion between intravascular ultrasound (IVUS) imaging and electromagnetic (EM) tracking was proposed. A new image processing method was presented to realize fully automatic processing of IVUS imaging and 3D reconstruction in real time, as well as branch detection for alignment and deployment. Complementary navigation using CT data allows for efficient catheter advancement and assistant clinical judgement.Results: The reconstruction of anin vitrodescending aorta phantom with branches was realized at 35 Hz, with cross‐section radius average error of 0.64 mm.Conclusion: The proposed method demonstrates significant potential for clinical applications, enables navigation for precise alignment and placement for stent grafting to reduce surgical time, and decreases hemorrhagic collisions and the use of contrast agent. Copyright © 2016 John Wiley & Sons, Ltd.Keywords
This publication has 29 references indexed in Scilit:
- Single-chip CMUT-on-CMOS front-end system for real-time volumetric IVUS and ICE imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014
- Current and Emerging Robot-Assisted Endovascular Catheterization Technologies: A ReviewAnnals of Biomedical Engineering, 2013
- Open Versus Endovascular Stent Graft Repair of Abdominal Aortic AneurysmsJACC: Cardiovascular Interventions, 2012
- Intravascular UltrasoundSeminars in Vascular Surgery, 2012
- Intravascular ultrasound with a vector phased-array probe (acunav) is feasible in endovascular abdominal aortic aneurysm repairActa Radiologica, 2009
- Endovascular Repair of Abdominal Aortic AneurysmNew England Journal of Medicine, 2008
- Abdominal aortic aneurysmThe Lancet, 2005
- Basics of intravascular ultrasound: An essential tool for the endovascular surgeonSeminars in Vascular Surgery, 2004
- Current status of open versus endovascular stent-graft repair of abdominal aortic aneurysmJournal of Vascular Surgery, 2004
- Contrast agent-associated nephrotoxicityProgress in Cardiovascular Diseases, 2003