Wash-free, label-free immunoassay for rapid electrochemical detection of PfHRP2 in whole blood samples
Open Access
- 20 November 2018
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-8
Abstract
Currently, the diagnosis of many diseases relies on laboratory-based immunoassays (ELISA, Western Blot), which are laborious, time-consuming and expensive. To address these limitations, we report a wash-free and label-free electrochemical immunoassay for rapid measurements of protein biomarkers in blood samples. This immunosensor employs a unique detection scheme based on electrochemical-chemical (EC) redox cycling for signal amplification combined with an affinity-based protein quantification strategy. All of the reagents required for this assay are dried and stored on a stacked membrane assembly, consisting of a Vivid Plasma Separation membrane and two cellulose membranes situated above the sensor, enabling excellent stability at room temperature for up to 2 months. Proof of concept was carried out by performing measurements of Plasmodium falciparum histidine-rich protein 2 (PfHRP2) in whole blood samples, which could be detected from 100 ng/mL to 100 µg/mL with excellent specificity and reproducibility. Each measurement requires only two liquid dispensing steps and can completed in 5 min, making this diagnostic platform promising for point-of-care testing in resource-limited settings.Keywords
This publication has 33 references indexed in Scilit:
- Electrochemical immunosensor for simultaneous detection of multiplex cancer biomarkers based on graphene nanocompositesBiosensors and Bioelectronics, 2013
- Direct comparison of the histidine-rich protein-2 enzyme-linked immunosorbent assay (HRP-2 ELISA) and malaria SYBR green I fluorescence (MSF) drug sensitivity tests in Plasmodium falciparum reference clones and fresh ex vivo field isolates from CambodiaMalaria Journal, 2013
- Defining Falciparum-Malaria-Attributable Severe Febrile Illness in Moderate-to-High Transmission Settings on the Basis of Plasma PfHRP2 ConcentrationThe Journal of Infectious Diseases, 2012
- Diagnosing Severe Falciparum Malaria in Parasitaemic African Children: A Prospective Evaluation of Plasma PfHRP2 MeasurementPLOS Medicine, 2012
- Performance of HRP-2 based rapid diagnostic test for malaria and its variation with age in an area of intense malaria transmission in southern tanzaniaMalaria Journal, 2010
- A disposable electrochemical immunosensor for carcinoembryonic antigen based on nano-Au/multi-walled carbon nanotubes–chitosans nanocomposite film modified glassy carbon electrodeAnalytica Chimica Acta, 2010
- Enzyme stability and stabilization—Aqueous and non-aqueous environmentProcess Biochemistry, 2008
- Enzyme-Linked Immunosorbent Assay for Detection of Plasmodium falciparum Histidine-Rich Protein 2 in Blood, Plasma, and SerumClinical and Vaccine Immunology, 2008
- Electrochemical biosensors: Towards point-of-care cancer diagnosticsBiosensors and Bioelectronics, 2006
- Point-of-care biosensor systems for cancer diagnostics/prognosticsBiosensors and Bioelectronics, 2006