Abstract
Untargeted mass spectrometry (MS) metabolomics is an increasingly popular approach for characterizing complex mixtures. Recent studies have highlighted the impact of data preprocessing for determining the quality of metabolomics data analysis. The first step in data processing with untargeted metabolomics requires that signal thresholds be selected for which features (detected ions) are included in the dataset. Analysts face the challenge of knowing where to set these thresholds; setting them too high could mean missing relevant features, but setting them too low could result in a complex and unwieldy dataset. This study compared data interpretation for an example metabolomics dataset when intensity thresholds were set at a range of feature heights. The main observations were that low signal thresholds (1) improved the limit of detection, (2) increased the number of features detected with an associated isotope pattern and/or an MS-MS fragmentation spectrum, and (3) increased the number of in-source clusters and fragments detected for known analytes of interest. When the settings of parameters differing in intensities were applied on a set of 39 samples to discriminate the samples through principal component analyses (PCA), similar results were obtained with both low- and high-intensity thresholds. We conclude that the most information-rich datasets can be obtained by setting low-intensity thresholds. However, in the cases where only a qualitative comparison of samples with PCA is to be performed, it may be sufficient to set high thresholds and thereby reduce the complexity of the data processing and amount of computational time required.Keywords
Funding Information
- Office of Dietary Supplements
- National Center for Complementary and Integrative Health (U41 AT008718)
This publication has 25 references indexed in Scilit:
- Opportunities and Limitations for Untargeted Mass Spectrometry Metabolomics to Identify Biologically Active Constituents in Complex Natural Product MixturesJournal of Natural Products, 2019
- One Step Forward for Reducing False Positive and False Negative Compound Identifications from Mass Spectrometry Metabolomics Data: New Algorithms for Constructing Extracted Ion Chromatograms and Detecting Chromatographic PeaksAnalytical Chemistry, 2017
- Comparison of Metabolomics Approaches for Evaluating the Variability of Complex Botanical Preparations: Green Tea (Camellia sinensis) as a Case StudyJournal of Natural Products, 2017
- A Conversation on Data Mining Strategies in LC-MS Untargeted Metabolomics: Pre-Processing and Pre-Treatment StepsMetabolites, 2016
- Prediction, Detection, and Validation of Isotope Clusters in Mass Spectrometry DataMetabolites, 2016
- MS-DIAL: data-independent MS/MS deconvolution for comprehensive metabolome analysisNature Methods, 2015
- Workflow4Metabolomics: a collaborative research infrastructure for computational metabolomicsBioinformatics, 2014
- Undetected Components in Natural Mixtures: How Many? What Concentrations? Do They Account for Chemical Noise? What Is Needed to Detect Them?Analytical Chemistry, 2011
- Tandem Mass Spectrometry for Sequencing ProanthocyanidinsAnalytical Chemistry, 2007
- XCMS: Processing Mass Spectrometry Data for Metabolite Profiling Using Nonlinear Peak Alignment, Matching, and IdentificationAnalytical Chemistry, 2006