- 11 January 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-3
Abstract
The future heavy ion synchrotron SIS100 will have series of two dc magnetic septa for the injection and three dc septa on the extraction line. The extraction line will allow for two different extraction schemes for vertical fast extraction and initially horizontal slow extraction. The latter requires among other components two additional Lambertson-type septa. The design of the magnets had to account not only for creating a high field with a narrow septum width. A way of providing bakeout jackets while limiting the technicians' exposure to radiation had to be found. Another issue was to minimise the chance of failure e. g. by limiting the number of soldered joints with contact to the cooling channels and by reducing the current density with help of wedgeshaped conductors. While the injection septa are under construction, still some design work is in process for the extraction septa. We will present some of our solutions and concepts.Keywords
This publication has 1 reference indexed in Scilit:
- Edge effect in charged-particle analyzing magnetsNuclear Instruments and Methods, 1964