Abstract
Background: Increasing expectancy of life and levels of activity in the growing geriatric population lead to a rising number of prosthetic implants of the hip and consequently the incidence of periprosthetic fractures of the femur increase. The fracture pattern and the possible instability of the stem are a challenge to the orthopaedic surgeon. Treatment options are complete replacement of the implant or a solitary osteosynthesis. The goal of this study was to analyse the feasibility of the operative intervention using a contralateral reversed anatomic distal femoral LISS® locking plate and the radiological and functional outcome in a geriatric cohort. Methods: We included all patients older than 75 years of age with a Vancouver type B fracture, which have been treated by osteosynthesis using a LISS® (contralateral reversed) plate in our institution in an interdisciplinary ortho-geriatric setting between 7/2013 and 12/2021. Perioperative morbidities, clinical and radiological outcome during follow-up were retrospectively analysed. Results: During the observed time period, 83 patients (mean age: 88 years (range: 76–103), male/female: 26/57) were treated. Most fractures were Vancouver type B2 (n = 45, 54%) followed by B1 (n = 20, 24%) and B3 (n = 18, 22%). The most prevalent postoperative surgical complication was anaemia (n = 73, 88%) followed by infections (n = 12, 14%, urinary infections, pneumonia) and cardiovascular decompensation (n = 8, 10%). Clinical and radiological follow up 6–8 weeks postoperative was possible for 59 patients (70%). The majority of them did not describe pain (n = 50, 85%) and had a good or excellent radiological outcome. Three cases needed revision surgery due to infection and another three due to non-union, loosening of the stem or an additional fracture. 1-year mortality was 30%. Conclusion: We are convinced that the reversed contralateral LISS-plate is an easy-to-use implant with a small complication rate but a very successful and high healing rate in a geriatric, polymorbid cohort.Keywords
This publication has 21 references indexed in Scilit:
- Epidemiology of periprosthetic fracture of the femur in 32 644 primary total hip arthroplastiesThe Bone & Joint Journal, 2016
- The Best Use of the Charlson Comorbidity Index With Electronic Health Care Database to Predict MortalityMedical Care, 2016
- Functional and radiological outcome of periprosthetic femoral fractures after hip arthroplastyInjury, 2015
- Preoperative predictors for mortality following hip fracture surgery: A systematic review and meta-analysisInjury, 2012
- A financial analysis of revision hip arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2012
- What is the financial cost of treating periprosthetic hip fractures?Injury, 2011
- Epidemiology of periprosthetic femur fracture around a total hip arthroplastyInjury, 2007
- Periprosthetic Fractures Evaluation and TreatmentClinical Orthopaedics and Related Research, 2004
- Fractures of the femur after hip replacement.1995
- GRADING OF PATIENTS FOR SURGICAL PROCEDURESAnesthesiology, 1941