Adaptive digital distance relay for SSSC‐based double‐circuit transmission line using phasor measurement unit
- 10 December 2018
- journal article
- research article
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 29 (4) , e2787
Abstract
The existence of midpoint series flexible alternating current transmission system (FACTS) devices leads to degrade the performance of mho relay, leading in erroneous estimation of fault location, ie, overreach or underreach for wide variation in network parameters. This research article proposes a novel mho relay algorithm to improve the performance of distance relay in presence of FACTS device using phasor measurement unit (PMU). First, the complete model of transmission system employing static synchronous series compensator (SSSC) and its control strategy is described analytically, where the error introduced in measurement of impedance due to SSSC on the performance of distance relay. Second, a novel mho relay procedure is developed based on PMU to protect the first zone of double‐circuit transmission line for single line‐to‐ground (SLG) fault. The proposed work is analysed and simulated with 48‐pulse SSSC carried out with Bergeron model of transmission line using power system computer‐aided design (PSCAD) computer simulation. Finally, the simulation results represent that the suggested adaptive scheme is truthful, reliable, and secure with change in compensation level of SSSC.Keywords
This publication has 25 references indexed in Scilit:
- Fractional-order PI based STATCOM and UPFC controller to diminish subsynchronous resonanceSpringerPlus, 2016
- Investigation for Improved Artificial Intelligence Techniques for Thyristor-controlled Series-compensated Transmission Line Fault Classification with Discrete Wavelet Packet Entropy MeasuresElectric Power Components and Systems, 2014
- Impact of VSC-Based Multiline FACTS Controllers on Distance Protection of Transmission LinesIEEE Transactions on Power Delivery, 2011
- Computer Relaying for Power Systems2009
- Performance of Distance Relays on Shunt—FACTS Compensated Transmission LinesIEEE Transactions on Power Delivery, 2005
- Operation of impedance protection relays with the STATCOMIEEE Transactions on Power Delivery, 2002
- Apparent Impedance Calculations for Distance-Protected Transmission Lines Employing Series-Connected FACTS DevicesElectric Power Components and Systems, 2001
- Adaptive relay setting for flexible AC transmission systems (FACTS)IEEE Transactions on Power Delivery, 2000
- SSSC-static synchronous series compensator: theory, modeling, and applicationIEEE Transactions on Power Delivery, 1998
- Power System Protection1998