A two-stage deep learning pipeline for automated detection and localization of endotracheal tubes on pediatric chest radiographs: a pilot study
Authors:
- Hailong LiHLHailong Li
- Bohan ZhangBZBohan Zhang
- Elanchezhian SomasundaramESElanchezhian Somasundaram
- Mahdieh ShabanianMSMahdieh Shabanian
- Zachary TaylorZTZachary Taylor
- Neeraja MahalingamNMNeeraja Mahalingam
- Zhixiu LuZLZhixiu Lu
- Bin ZhangBZBin Zhang
- Stephen W. StandageSSStephen W. Standage
- Gary R. SchoolerGSGary R. Schooler
- Lili HeLHLili He
- Alexander J. TowbinATAlexander J. Towbin
Open Access
- 11 September 2026
- journal article
- research article
- Published by Springer Nature in Pediatric Radiology
- p. 1-14
Abstract
Background: Endotracheal tubes (ETTs) are critical life-support devices for mechanically ventilated pediatric patients, yet automated ETT assessment on pediatric chest radiographs (CXRs) remains limited. Objective: To develop and evaluate a two-stage deep learning pipeline for automated detection and localization of ETTs on pediatric CXRs. Materials and methods: This retrospective study included 1,000 pediatric CXRs (476 ETT-positive, 524 ETT-negative) acquired in 2021 at a single institution. ETT segmentation masks and distal tip coordinates were annotated by trained analysts and verified by pediatric radiologists. A two-stage pipeline consisting of a ResNet classification model followed by a U-Net segmentation model was developed for ETT detection and localization. Performance was evaluated on a held-out test set using multiple metrics, including the area under the receiver operating characteristic curve (AUROC) and the mean absolute error (MAE), with 95% confidence intervals (CI). Inter-observer variability was assessed as a reference for localization performance. Results: Inter-observer variability for ETT tip localization was 2.01 mm MAE on the held-out test set. The pipeline achieved an AUROC of 0.994 (95% CI 0.986, 1.000) for ETT detection. For localization, the pipeline achieved a MAE of 6.59 mm (95% CI 5.19, 8.21 mm). Incorporating the classification stage substantially reduced false-positive segmentations from 17 to 3 among ETT-negative CXRs compared with the standalone segmentation model. Conclusion: A two-stage deep learning pipeline demonstrated high performance for automated ETT detection and promising performance for tip localization on pediatric CXRs in this single-center pilot study. Further evaluation in larger and external pediatric cohorts is needed to assess generalizability.Keywords
This publication has 34 references indexed in Scilit:
- Pediatric chest radiograph interpretation: how far has artificial intelligence come? A systematic literature reviewPediatric Radiology, 2022
- Measurement of Endotracheal Tube Positioning on Chest X-Ray Using Object DetectionJournal of Digital Imaging, 2021
- Automatic Detection and Classification of Multiple Catheters in Neonatal Radiographs with Deep LearningJournal of Digital Imaging, 2021
- Identification and Localization of Endotracheal Tube on Chest Radiographs Using a Cascaded Convolutional Neural Network ApproachJournal of Digital Imaging, 2021
- Could automated analysis of chest X-rays detect early bronchiectasis in children?European Journal of Pediatrics, 2021
- Automatic Catheter and Tube Detection in Pediatric X-ray Images Using a Scale-Recurrent Network and Synthetic DataJournal of Digital Imaging, 2019
- Deep Convolutional Neural Networks for Endotracheal Tube Position and X-ray Image Classification: Challenges and OpportunitiesJournal of Digital Imaging, 2017
- U-Net: Convolutional Networks for Biomedical Image Segmentation2015
- Endotracheal tube malposition within the pediatric population: a common event despite clinical evidence of correct placementCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2008
- Contrast Limited Adaptive Histogram Equalization1994