Enhanced Analyte Detection Using In-Source Fragmentation of Field Asymmetric Waveform Ion Mobility Spectrometry-Selected Ions in Combination with Time-of-Flight Mass Spectrometry
- 28 March 2012
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 84 (9) , 4095-4103
Abstract
Miniaturized ultra high field asymmetric waveform ion mobility spectrometry (FAIMS) is used for the selective transmission of differential mobility-selected ions prior to in-source collision-induced dissociation (CID) and time-of-flight mass spectrometry (TOFMS) analysis. The FAIMS-in-source collision induced dissociation-TOFMS (FISCID-MS) method requires only minor modification of the ion source region of the mass spectrometer and is shown to significantly enhance analyte detection in complex mixtures. Improved mass measurement accuracy and simplified product ion mass spectra were observed following FAIMS preselection and subsequent in-source CID of ions derived from pharmaceutical excipients, sufficiently close in m/z (17.7 ppm mass difference) that they could not be resolved by TOFMS alone. The FISCID-MS approach is also demonstrated for the qualitative and quantitative analysis of mixtures of peptides with FAIMS used to filter out unrelated precursor ions thereby simplifying the resulting product ion mass spectra. Liquid chromatography combined with FISCID-MS was applied to the analysis of coeluting model peptides and tryptic peptides derived from human plasma proteins, allowing precursor ion selection and CID to yield product ion data suitable for peptide identification via database searching. The potential of FISCID-MS for the quantitative determination of a model peptide spiked into human plasma in the range of 0.45–9.0 μg/mL is demonstrated, showing good reproducibility (%RSD < 14.6%) and linearity (R2 > 0.99).Keywords
This publication has 24 references indexed in Scilit:
- Differential Ion Mobility Spectrometry2008
- Ion mobility–mass spectrometryJournal of Mass Spectrometry, 2008
- Ion mobility spectrometry: a review. Part 1. Structural analysis by mobility measurementThe Analyst, 2004
- Comparison of Dissociation of Ions in an Electrospray Source, or a Collision Cell in Tandem Mass SpectrometryCurrent Organic Chemistry, 2003
- Tandem mass spectra of tryptic peptides at signal‐to‐background ratios approaching unity using electrospray ionization high‐field asymmetric waveform ion mobility spectrometry/hybrid quadrupole time‐of‐flight mass spectrometryRapid Communications in Mass Spectrometry, 2002
- Ion Trap/Ion Mobility/Quadrupole/Time-of-Flight Mass Spectrometry for Peptide Mixture AnalysisAnalytical Chemistry, 2000
- Evaluation of carrier gases for use in high-field asymmetric waveform ion mobility spectrometryJournal of the American Society for Mass Spectrometry, 2000
- Mass spectrometric characterization of a high-field asymmetric waveform ion mobility spectrometerReview of Scientific Instruments, 1998
- A new method of separation of multi-atomic ions by mobility at atmospheric pressure using a high-frequency amplitude-asymmetric strong electric fieldInternational Journal of Mass Spectrometry and Ion Processes, 1993
- Principles of collisional activation in analytical mass spectrometryJournal of the American Society for Mass Spectrometry, 1992