Objectives: The auditory brainstem implant (ABI) provides sound awareness to patients who are ineligible for cochlear implantation. Auditory performance varies widely among similar ABI cohorts. We hypothesize that differences in electrode array position contribute to this variance. Herein, we classify ABI array position based on postoperative imaging and investigate the relationship between position and perception. Design: Retrospective review of pediatric and adult ABI users with postoperative computed tomography. To standardize views across subjects, true axial reformatted series of scans were created using the McRae line. Using multiplanar reconstructions, basion and electrode array tip coordinates and array angles from vertical were measured. From a lateral view, array angles (V) were classified into types I to IV, and from posterior view, array angles (T) were classified into types A to D. Array position was further categorized by measuring distance vertical from basion (D1) and lateral from midline (D2). Differences between array classifications were compared with audiometric thresholds, number of active electrodes, and pitch ranking. Results: Pediatric (n = 4, 2 with revisions) and adult (n = 7) ABI subjects were included in this study. Subjects had a wide variety of ABI array angles, but most were aimed superiorly and posteriorly (type II, n = 7) from lateral view and upright or medially tilted from posterior view (type A, n = 6). Mean pediatric distances were 8 to 42% smaller than adults for D1 and D2. In subjects with perceptual data, electrical thresholds and the number of active electrodes differed among classification types. Conclusions: In this first study to classify ABI electrode array orientation, array position varied widely. This variability may explain differences in auditory performance.Keywords
This publication has 36 references indexed in Scilit:
- Accuracy and Reliability of Length Measurements on Three-Dimensional Computed Tomography Using Open-Source OsiriX SoftwareJournal of Digital Imaging, 2012
- Evaluation of the implanted cochlear implant electrode by CT scanning with three-dimensional reconstructionActa Oto-Laryngologica, 2011
- Morphological and morphometric study on sphenoid and basioccipital ossification in normal human fetusesCongenital Anomalies, 2011
- Hearing improvement after cochlear implantation in common cavity malformed cochleae: long-term follow-up resultsActa Oto-Laryngologica, 2011
- CT evaluation of Chamberlain's, McGregor's, and McRae's skull-base linesClinical Radiology, 2009
- Real-Time Intraoperative Computed Tomography to Assist Cochlear Implant Placement in the Malformed Inner EarOtology & Neurotology, 2009
- Open Set Speech Perception with Auditory Brainstem Implant?The Laryngoscope, 2005
- Auditory Brainstem Implant (ABI): New Frontiers in Adults and ChildrenOtolaryngology–Head and Neck Surgery, 2005
- OsiriX: An Open-Source Software for Navigating in Multidimensional DICOM ImagesJournal of Digital Imaging, 2004
- A New Classification for Cochleovestibular MalformationsThe Laryngoscope, 2002