Children and Adolescents’ Anthropometrics Body Composition from 3‐D Optical Surface Scans
Open Access
- 5 November 2019
- Vol. 27 (11) , 1738-1749
Abstract
Objective: This study aimed to explore the accuracy and precision of three‐dimensional optical (3DO) whole‐body scanning for automated anthropometry and estimating total and regional body composition.Methods: Healthy children and adolescents (n = 181, ages 5‐17 years) were recruited for the Shape Up! Kids study. Each participant underwent whole‐body dual‐energy x‐ray absorptiometry and 3DO scans; multisite conventional tape measurements served as the anthropometric criterion measure. 3DO body shape was described using automated body circumference, length, and volume measures. 3DO estimates were compared with criterion measures using simple linear regression by the stepwise selection method.Results: Of the 181 participants, 112 were used for the training set, 49 were used for the test set, and 20 were excluded for technical reasons. 3DO body composition estimates were strongly associated with dual‐energy x‐ray absorptiometry measures for percent body fat, fat mass, and fat‐free mass (R2: 0.83, 0.96, and 0.98, respectively). 3DO provided reliable measurements of fat mass (coefficient of variation, 3.30; root mean square error [RMSE], 0.53), fat‐free mass (coefficient of variation, 1.34; RMSE, 0.53 kg), and percent body fat (RMSE = 1.2%).Conclusions: 3DO surface scanning provides accurate and precise anthropometric and body composition estimates in children and adolescents with high precision. 3DO is a safe, accessible, and practical method for evaluating body shape and composition in research and clinical settings.Keywords
Funding Information
- National Institute of Diabetes and Digestive and Kidney Diseases (NIH R01 DK111698)
This publication has 27 references indexed in Scilit:
- Dual‐Energy X‐Ray Performs as Well as Clinical Computed Tomography for the Measurement of Visceral FatObesity, 2012
- Dual-energy X-ray absorptiometry–based body volume measurement for 4-compartment body compositionThe American Journal of Clinical Nutrition, 2012
- Optimal monitoring time interval between DXA measures in childrenJournal of Bone and Mineral Research, 2011
- Obesity in ChildrenJournal of Clinical Research in Pediatric Endocrinology, 2011
- Dual Energy X-Ray Absorptiometry Body Composition Reference Values from NHANESPLOS ONE, 2009
- Comparison of dual-energy X-ray absorptiometry, air displacement plethysmography and bioelectrical impedance analysis for the assessment of body composition in severely obese Caucasian children and adolescentsBritish Journal of Nutrition, 2008
- A Generalized Least Significant Change for Individuals Measured on Different DXA SystemsJournal of Clinical Densitometry, 2007
- Body Composition in Athletes: Assessment and Estimated FatnessClinics in Sports Medicine, 2007
- Underestimation of percentage fat mass measured by bioelectrical impedance analysis compared to dual energy X-ray absorptiometry method in obese childrenEuropean Journal of Clinical Nutrition, 2001
- Accurate assessment of precision errors: How to measure the reproducibility of bone densitometry techniquesOsteoporosis International, 1995