Use of image analysis in DC inclined plane tracking tests of nano and micro composites
Authors:
- L E SchmidtLSL E Schmidt
- 28 March 2011
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 18 (2) , 365-374
Abstract
Leakage current magnitude is used as one of the failure criteria in the tracking and erosion test IEC 60587. The 3rd harmonic is also often used to identify periods of arcing activity. This technique is not available for the equivalent dc test. This paper presents the use of a machine vision camera alongside measurements of leakage current to identify discharge activity during dc testing and so enable determination of arc intermittency. This simple image processing technique is shown to add significant value to the existing leakage current analysis techniques and can provide an understanding of the process of degradation and its dependence on voltage polarity. Tests are reported on a commercial silicone rubber compound, a micro-filled epoxy resin, and the same epoxy resin system with nano particle fillers at 5% by weight. It is shown that the technique is applicable to this wide range of materials. It is also shown that changes to the performance of the epoxy compound by the addition of nano filler is due to more than just improving discharge resistance, reported elsewhere. The wettability of the samples is seen to be important, controlling moisture flow during a test. For this reason, in the case of the top electrode being positive, the nano filled material failed the test earlier than the standard material, with reduced erosion but increased leakage current.Keywords
This publication has 11 references indexed in Scilit:
- Space charge behaviour on epoxy based dielectrics filled with micro and nano silica2010
- Effects of nano-filler addition on partial discharge resistance and dielectric breakdown strength of Micro-Al2O3Epoxy compositeIEEE Transactions on Dielectrics and Electrical Insulation, 2010
- Performance of silicone rubber in DC inclined plane tracking testsIEEE Transactions on Dielectrics and Electrical Insulation, 2010
- A comparative study of insulator materials exposed to high voltage AC and DC surface dischargesIEEE Transactions on Dielectrics and Electrical Insulation, 2010
- Inclined-plane tracking and erosion test according to the IEC 60587 StandardIEEE Electrical Insulation Magazine, 2009
- A Technique for the Optical Detection and Analysis of Dry Band Arcs on a Composite Insulator2008
- Investigation of Tracking Phenomena in Outdoor Polymeric Insulation Material Under DC Voltages Using WaveletsIEEE Transactions on Power Delivery, 2005
- Correlation of damage, dry band arcing energy, and temperature in inclined plane testing of silicone rubber for outdoor insulationIEEE Transactions on Dielectrics and Electrical Insulation, 2004
- AC and DC performance of polymeric housing materials for HV outdoor insulatorsIEEE Transactions on Dielectrics and Electrical Insulation, 1999
- Surface electrical failure in the presence of contaminants: The inclined-plane liquid-contaminant testTransactions of the American Institute of Electrical Engineers, Part I: Communication and Electronics, 1961