Intraoperative neurophysiological monitoring during spinal surgery: technical review in open and minimally invasive approaches
- 8 January 2018
- journal article
- review article
- Published by Springer Nature in Neurosurgical Review
- Vol. 42 (2) , 297-307
Abstract
Neurophysiological monitoring is of undoubted value for the intraoperative safety of neurosurgical procedures. Widely developed and used for cranial surgery, it is equally as effective, though perhaps less commonly employed, for spinal pathology. The most frequently used techniques for intraoperative monitoring during spinal surgery include somatosensory evoked potentials (SSEPs), motor evoked potentials (MEPs) and electromyography, which can either be spontaneous free-running (sEMG) or triggered (tEMG). The knowledge of the benefits and limitations of each modality is essential in optimising the value of intraoperative monitoring during spinal procedures. This review will analyse the single techniques, their anatomical and physiological basis, their use in spinal surgery as reliable indicators of functional injury, their limits and their application to specific procedures in minimally invasive surgery, such as the lateral transpsoas access for interbody fusion and the divergent trajectory for cortico-pedicular screws. In these particular techniques, because of reduced visual exposure, neuromonitoring is indeed essential to exploit the full potential of minimally invasive surgery, while avoiding damage to nervous structures.Keywords
This publication has 57 references indexed in Scilit:
- A review of intraoperative monitoring for spinal surgerySurgical Neurology International, 2012
- Trajectory of the main sensory and motor branches of the lumbar plexus outside the psoas muscle related to the lateral retroperitoneal transpsoas approachJournal of Neurosurgery: Spine, 2011
- Intraoperative and Early Postoperative Complications in Extreme Lateral Interbody FusionSpine, 2011
- Defining the safe working zones using the minimally invasive lateral retroperitoneal transpsoas approach: an anatomical studyJournal of Neurosurgery: Spine, 2010
- The Relationship of Intrapsoas Nerves During a Transpsoas Approach to the Lumbar SpineJournal of Spinal Disorders & Techniques, 2010
- An anatomical study of the lumbosacral plexus as related to the minimally invasive transpsoas approach to the lumbar spineJournal of Neurosurgery: Spine, 2009
- Neurophysiological detection of iatrogenic C-5 nerve deficit during anterior cervical spinal surgeryJournal of Neurosurgery: Spine, 2007
- Somatosensory- and motor-evoked potential monitoring during spine and spinal cord surgerySpinal Cord, 2006
- Pedicle Screws With High Electrical ResistanceSpine, 2002
- Stimulation of the cerebral cortex in the intact human subjectNature, 1980