Correcting temperature dependence in miniature spectrometers used in cold polar environments
- 6 April 2015
- journal article
- Published by Optica Publishing Group in Applied Optics
- Vol. 54 (11) , 3162-3172
Abstract
Measurement biases arising from changes in temperature can be a major concern when using miniature spectrometers in extreme environments, particularly when temperature stabilization approaches are not feasible. Here, temperature-related biases of a low-power field spectrometry system comprised of a CMOS miniature monolithic spectrometer module and custom driver electronics were examined between and , well below the stated operating range of this particular spectrometer. Using these observations, a predictive model was developed to estimate the dark output of the spectrometry system within this extended operating range. This information was used to correct the signal at any measured integration time and temperature to that which would be measured at a reference integration time and temperature. This approach provides a general framework for assessing the temperature dependence of monolithic spectrometers whose field use will occur at temperatures outside of the range examined by the manufacturer.
Keywords
Funding Information
- China Scholarship Council (CSC)
- Program for Zhejiang Leading Team of S&T Innovation (2010R50036)
- Woods Hole Oceanographic Institution (WHOI)
This publication has 11 references indexed in Scilit:
- A Fiber Optic Spectrometry System for Measuring Irradiance Distributions in Sea Ice EnvironmentsJournal of Atmospheric and Oceanic Technology, 2014
- Temperature and nonlinearity corrections for a photodiode array spectrometer used in the fieldApplied Optics, 2011
- Dark Signal Temperature Dependence Correction Method for Miniature Spectrometer ModulesJournal of Sensors, 2011
- Design of a hyperspectral nitrogen sensing system for orange leavesComputers and Electronics in Agriculture, 2008
- Application of commercially available, low-cost, miniaturised NIR spectrometers to the assessment of the sugar content of intact fruitAustralian Journal of Plant Physiology, 2000
- A portable flow-injection instrument incorporating a miniature spectrometer for the real-time monitoring of nitrate in riversLaboratory Robotics and Automation, 2000
- The Southampton underwater multiparameter optical-fibre spectrometer system (SUMOSS)Measurement Science and Technology, 1999
- Flexible fiber-optic-based underwater spectrometer for oceanographic research1997
- Multiple excitation fluorometer for in situ oceanographic applicationsApplied Optics, 1997
- Temperature sensitivity characterization of a silicon diode array spectrometerRemote Sensing of Environment, 1995