Abstract
This prospective study tested a simple formula for selecting an implant size for patients undergoing enucleation, evisceration, and secondary implantation. The formula axial length-2 mm=implant diameter (subtract 1 mm from implant diameter for evisceration and for hyperopia) was tested by the outcome measures, superior sulcus deformity, enophthalmos, and volume of the prosthesis. Fifty-four patients undergoing primary or secondary implant surgery after enucleation or evisceration received implants based on the above formula. The volume of the eye, volume of the implant, volume of the prosthesis, and the total percent volume replacement were recorded for each patient. Outcome measures considered clinically acceptable were or =2 mm despite 100% volume replacement. Further study will elucidate the histopathologic processes responsible for residual superior sulcus deformity and enophthalmos in the latter subgroup of patients.