Effect of Anesthesia on Intraocular Pressure Measured With Continuous Wireless Telemetry in Nonhuman Primates
Open Access
- 3 September 2019
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 60 (12) , 3830-3834
Abstract
Purpose: To compare the effects of both injectable anesthesia (ketamine/dexmedetomidine versus ketamine/xylazine) and inhalant anesthesia (isoflurane) on IOP using continuous, bilateral IOP telemetry in nonhuman primates (NHP). Methods: Bilateral IOP was recorded continuously using a proven implantable telemetry system in five different sessions at least 2 weeks apart in four male rhesus macaques under two conditions: ketamine (3 mg/kg) with dexmedetomidine (50 μg/kg) or ketamine with xylazine (0.5 mg/kg) for induction, both followed by isoflurane for maintenance. IOP transducers were calibrated via anterior chamber manometry. Bilateral IOP was averaged over 2 minutes after injectable anesthetic induction and again after isoflurane inhalant had stabilized the anesthetic plane, then compared to baseline IOP measurements acquired immediately prior to anesthesia (both before and after initial human contact). Results: When compared to pre-contact baseline measurements, ketamine/dexmedetomidine injectable anesthesia lowers IOP by 1.5 mm Hg on average (P < 0.05), but IOP did not change with ketamine/xylazine anesthesia. IOP returned to baseline levels shortly after isoflurane gas anesthesia was initiated. However, injectable anesthesia lowered IOP by an average of 5.4 mm Hg when compared to that measured after initial human contact (P < 0.01). Conclusions: Anesthetic effects on IOP are generally small when compared to precontact baseline but much larger when compared to IOP measures taken after human contact, indicating that IOP is temporarily elevated due to acute stress (similar to a “white coat effect”) and then decreased with anesthetic relaxation. Anesthetic induction with ketamine/xylazine and maintenance with isoflurane gas should be used when IOP is measured postanesthesia.Keywords
This publication has 27 references indexed in Scilit:
- 24-Hour IOP Telemetry in the Nonhuman Primate: Implant System Performance and Initial Characterization of IOP at Multiple TimescalesInvestigative Ophthalmology & Visual Science, 2011
- Effect of general anesthetics on IOP in elevated IOP mouse modelExperimental Eye Research, 2011
- Duration of Anesthesia Affects Intraocular Pressure, But Not Outflow Facility in MiceCurrent Eye Research, 2010
- Rebound Tonometry in Conscious, Conditioned Mice Avoids the Acute and Profound Effects of Anesthesia on Intraocular PressureJournal of Ocular Pharmacology and Therapeutics, 2008
- Effect of Daily Prolonged Ketamine Anesthesia on Intraocular Pressure in MonkeysCurrent Eye Research, 2008
- Dexmedetomidine during local anesthesiaJournal of Anesthesia, 2006
- Immobilization Stress Induces Elevation of Intraocular Pressure in RabbitsOphthalmic Research, 2000
- Stress reactivity of intraocular pressure after relaxation training in open-angle glaucoma patientsJournal of Behavioral Medicine, 1996
- Stress and intraocular pressure in myopesPsychology & Health, 1992
- Ketamine and Intraocular Pressure in ChildrenAnesthesia & Analgesia, 1976