MRI and its role in the evaluation and surgical decision making in patients with challenging IPP presentations: descriptions of MRI findings and algorithm for patient management
Authors:
- 28 October 2011
- journal article
- research article
- Published by Wiley in BJU International
- Vol. 109 (12) , 1848-1852
Abstract
Study Type – Diagnostic (case series) Level of Evidence 4 What's known on the subject? and What does the study add? It is known that magnetic resonance imaging (MRI) is safe and effective for imaging patients with inflatable penile prostheses (IPPs). Previous series have reported results of MRI for imaging series of patients with IPPs. The impact on management in particular with regard to salvage procedures is not well defined. This study represents the largest known experience with MRI evaluation of IPPs. This also provides an algorithm that assists with decisions regarding utilization of MRI and treatment planning based on results. OBJECTIVE: In some patients who undergo placement of an inflatable penile prosthesis (IPP) the device may function inadequately. We describe the use of magnetic resonance imaging (MRI) for anatomical localization and detection of prosthesis malrotation, angulation, displacement and erosion in IPPs with equivocal clinical examination. PATIENTS AND METHODS: We prospectively performed MRI by a defined protocol including T1‐weighted imaging, and transaxial, sagittal and coronal fat‐saturated fast spin‐echo T2‐weighted imaging in both deflated and inflated states to evaluate patients seen at our referral centre for IPP‐related complaints. We retrospectively reviewed 32 such MRI studies performed as a supplement to clinical examination between 2000 and 2008. RESULTS: Of 32 cases, 75% (24/32) underwent surgical intervention. Of these, 45% (11/24) underwent device salvage procedures including cylinder revision in 33% (8/24), cylinder replacement in 8% (2/24) and pump replacement in 4% (1/24). MRI was most useful for determination of surgical approach in those with abnormal physical examination, and for justification of either surgical or expectant management in those with indeterminate physical examination. CONCLUSIONS: MRI is safe and effective for imaging genitourinary prostheses. We found MRI to be a valuable adjunct for evaluation of IPP‐related complaints when clinical examination is equivocal as it detected a variety of prosthetic and corporal abnormalities and impacted management decisions regarding observation, replacement or device salvage procedures. We provide technique, results and an algorithm that can be beneficial in this complex subset of patients.Keywords
This publication has 11 references indexed in Scilit:
- MR Imaging of Nonmalignant Penile LesionsRadioGraphics, 2008
- Factors influencing the outcomes of penile prosthesis surgery at a teaching institutionUrology, 2003
- Utility of magnetic resonance imaging in evaluating inflatable penile prosthesis malfunction and complaintsInternational Journal Of Impotence Research, 2003
- Distal penile prosthesis extrusion: treatment with distal corporoplasty or Gortex windsock reinforcementInternational Journal Of Impotence Research, 2002
- AMS Three–Piece Inflatable Implants for Erectile Dysfunction: A Long–Term Multi–Institutional Study in 200 Consecutive PatientsEuropean Urology, 2000
- Long-term mechanical reliability of multicomponent inflatable penile prosthesis: comparison of device survivalUrology, 1998
- BUCKLING OF CYLINDERS MAY CAUSE PROLONGED PENILE PAIN AFTER PROSTHESIS IMPLANTATION: A CASE CONTROL STUDY USING MAGNETIC RESONANCE IMAGING OF THE PENISJournal of Urology, 1998
- MR imaging and biomedical implants, materials, and devices: an updated review.Radiology, 1991
- Normal penile anatomy and abnormal penile conditions: evaluation with MR imaging.Radiology, 1988
- Salvage of the Eroded Inflatable Penile Prosthesis: A New ConceptJournal of Urology, 1987