Bench to Bedside: Electrophysiologic and Clinical Principles of Noninvasive Hemodynamic Monitoring Using Impedance Cardiography
- 28 June 2003
- journal article
- review article
- Published by Wiley in Academic Emergency Medicine
- Vol. 10 (6) , 669-680
Abstract
The evaluation of the hemodynamic state of the severely ill patient is a common problem in emergency medicine. While conventional vital signs offer some insight into delineating the circulatory pathophysiology, it is often impossible to determine the true clinical state from an analysis of blood pressure and heart rate alone. Cardiac output measurements by thermodilution have been the criterion standard for the evaluation of hemodynamics. However, this technology is invasive, expensive, time‐consuming, and impractical for most emergency department environments. Impedance cardiography (ICG) is a noninvasive method of obtaining continuous measurements of hemodynamic data such as cardiac output that requires little technical expertise. ICG technology was first developed by NASA in the 1960s and is based on the idea that the human thorax is electrically a nonhomogeneous, bulk conductor. Variation in the impedance to flow of a high‐frequency, low‐magnitude alternating current across the thorax results in the generation of a measured waveform from which stroke volume can be calculated by a modification of the pulse contour method. To adequately judge the possible role of this technology in the practice of emergency medicine, it is important to have a sufficient understanding of the basic scientific principles involved as well as the clinical validity and limitations of the technique.Keywords
This publication has 24 references indexed in Scilit:
- The Historical Evolution of BioimpedanceAACN Advanced Critical Care, 1999
- Intensive Care Unit Care in the Emergency Department?Academic Emergency Medicine, 1999
- Differentiating systolic from diastolic heart failure using impedance cardiography.Academic Emergency Medicine, 1999
- Prediction of pulmonary capillary wedge pressure and assessment of stroke volume by noninvasive impedance cardiographyAmerican Heart Journal, 1997
- Unreliability of blood pressure and heart rate to evaluate cardiac output in emergency resuscitation and critical illnessCritical Care Medicine, 1993
- Systolic and diastolic time intervals in the critically ill patientCritical Care Medicine, 1991
- The use of transthoracic electrical bioimpedance in assessing thoracic fluid status in emergency department patientsThe American Journal of Emergency Medicine, 1988
- MEASUREMENT OF EJECTION FRACTION BY BIOIMPEDANCE METHODCritical Care Medicine, 1987
- A new stroke volume equation for thoracic electrical bioimpedanceCritical Care Medicine, 1986
- The Relationship of Alterations in Systolic Time Intervals to Ejection Fraction in Patients with Cardiac DiseaseCirculation, 1970