Technical Principles and Clinical Applications of Electrical Impedance Tomography in Pulmonary Monitoring
Open Access
Abstract
Pulmonary monitoring is crucial for the diagnosis and management of respiratory conditions, especially after the epidemic of coronavirus disease. Electrical impedance tomography (EIT) is an alternative non-radioactive tomographic imaging tool for monitoring pulmonary conditions. This review proffers the current EIT technical principles and applications on pulmonary monitoring, which gives a comprehensive summary of EIT applied on the chest and encourages its extensive usage to clinical physicians. The technical principles involving EIT instrumentations and image reconstruction algorithms are explained in detail, and the conditional selection is recommended based on clinical application scenarios. For applications, specifically, the monitoring of ventilation/perfusion (V/Q) is one of the most developed EIT applications. The matching correlation of V/Q could indicate many pulmonary diseases, e.g., the acute respiratory distress syndrome, pneumothorax, pulmonary embolism, and pulmonary edema. Several recently emerging applications like lung transplantation are also briefly introduced as supplementary applications that have potential and are about to be developed in the future. In addition, the limitations, disadvantages, and developing trends of EIT are discussed, indicating that EIT will still be in a long-term development stage before large-scale clinical applications.Keywords
This publication has 108 references indexed in Scilit:
- A measure of the information content of EIT dataPhysiological Measurement, 2008
- Imaging of conductivity changes and electrode movement in EITPhysiological Measurement, 2006
- Regional lung perfusion as determined by electrical impedance tomography in comparison with electron beam CT imagingIEEE Transactions on Medical Imaging, 2002
- A comparison of methods for measurement of spatial resolution in two-dimensional circular EIT imagesPhysiological Measurement, 2002
- Mechanical impedance of the human body in vertical directionApplied Ergonomics, 2000
- Electrical Impedance Tomography in the Assessment of Extravascular Lung Water in Noncardiogenic Acute Respiratory FailureChest, 1999
- Errors in prolonged electrical impedance measurements due to electrode repositioning and postural changesPhysiological Measurement, 1995
- A wide-band AC-coupled current source for electrical impedance tomographyPhysiological Measurement, 1994
- Bioelectrical spectroscopy from multi-frequency EITPhysiological Measurement, 1994
- Image reconstruction using non-adjacent drive configurations (electric impedance tomography)Physiological Measurement, 1994