Quantitative assessment of diffuse coronary artery disease using a three-dimensional reconstruction method compared with intravascular ultrasound images
Authors:
- Masami ShimizuMSMasami Shimizu
- Hiroyuki YoshioHYHiroyuki Yoshio
- Hidekazu InoHIHidekazu Ino
- Kazuyasu OkeieKOKazuyasu Okeie
- Toshihiko YasudaTYToshihiko Yasuda
- Hiroshi MabuchiHMHiroshi Mabuchi
- 1 March 2001
- journal article
- Published by Wolters Kluwer Health in Coronary Artery Disease
- Vol. 12 (2) , 127-133
Abstract
It can be difficult to estimate the degree of stenosis in patients with diffuse coronary artery disease (CAD), because of the lack of a normal reference segment. If the size of normal coronary lumen has a direct relation to size of distal myocardial bed, it could be used to estimate the 'normal' cross-sectional area of coronary lumen. Accordingly, we could estimate the degree of stenosis of coronary arteries with diffuse disease by comparing them with calculated 'normal' areas of lumen. To assess the validity of the above hypothesis. Fourteen subjects without coronary atherosclerosis (group A) and 16 patients with CAD (group B) underwent simultaneous bidirectional coronary arteriography. Using these coronary arteriograms, we determined the relationship between cross-sectional area of coronary lumen measured by using a computerized edge-detection system and summed distal branch length calculated by using our computerized three-dimensional reconstruction method. For group A, we found a close correlation between area of lumen and branch length (r= 0.948). However, for group B, there were some segments for which the measured area of lumen was clearly smaller than that expected from the relationship for group A. From this relationship for group A, we calculated the stenosis ratios of 22 segments and, to confirm their accuracy, we compared the stenotic ratios with those measured on intravascular ultrasound images. The stenotic ratio of each segment of stenotic coronary artery calculated by our method agreed significantly well with the results obtained from the ultrasound measurements (r= 0.980). These observations validate a novel approach to quantifying diffuse CAD using clinical arteriograms.Keywords
This publication has 13 references indexed in Scilit:
- Intracoronary ultrasound imaging: Correlation of plaque morphology with angiography, clinical syndrome and procedural results in patients undergoing coronary angioplastyJACC, 1993
- Intravascular ultrasound of the coronary arteries: Current applications and future directionsThe American Journal of Cardiology, 1992
- Intravascular ultrasound imaging: A current perspectiveJACC, 1991
- Three-dimensional reconstruction of moving arterial beds from digital subtraction angiographyComputers and Biomedical Research, 1987
- Regional myocardial volume perfused by the coronary artery branch: estimation in vivo.Circulation, 1986
- Three-Dimensional Left Ventricular Wall Motion in ManInvestigative Radiology, 1984
- Cross-sectional area of the proximal portions of the three major epicardial coronary arteries in 98 necropsy patients with different coronary events. Relationship to heart weight, age and sex.Circulation, 1980
- Correlation of age and heart weight with tortuosity and caliber of normal human coronary arteriesAmerican Heart Journal, 1977
- Angiographic Estimation of Relative Coronary Artery Flow Based on Terminal Branching PatternsCatheterization and Cardiovascular Diagnosis, 1975
- Relation between coronary artery size and left ventricular wall mass.Heart, 1973