Three-Dimensional Mapping of Shear Wave Velocity in Human Tendon: A Proof of Concept Study
Open Access
Abstract
Ultrasound-based shear wave elastography (SWE) provides the means to quantify tissue mechanical properties in vivo and has proven valuable in detecting degenerative processes in tendons. Its current mode of use is for two-dimensional rendering measurements, which are highly position-dependent. We therefore propose an approach to create a volumetric reconstruction of the mechano-acoustic properties of a structure of interest based on optically tracking the ultrasound probe during free-hand measurement sweeps. In the current work, we aimed (1) to assess the technical feasibility of the three-dimensional mapping of unidirectional shear wave velocity (SWV), (2) to evaluate the possible artefacts associated with hand-held image acquisition, (3) to investigate the reproducibility of the proposed technique, and (4) to study the potential of this method in detecting local adaptations in a longitudinal study setting. Operative and technical feasibility as well as potential artefacts associated with hand-held image acquisition were studied on a synthetic phantom containing discrete targets of known mechanical properties. Measurement reproducibility was assessed based on inter-day and inter-reader scans of the patellar, Achilles, and supraspinatus tendon of ten healthy volunteers and was compared to traditional two-dimensional image acquisition. The potential of this method in detecting local adaptations was studied by testing the effect of short-term voluntary isometric loading history on SWV along the tendon long axis. The suggested approach was technically feasible and reproducible, with a moderate to very good reliability and a standard error of measurement in the range of 0.300–0.591 m/s for the three assessed tendons at the two test-retest modalities. We found a consistent variation in SWV along the longitudinal axis of each tendon, and isometric loading resulted in regional increases in SWV in the patellar and Achilles tendons. The proposed method outperforms traditional two-dimensional measurement with regards to reproducibility and may prove valuable in the objective assessment of pathological tendon changes.Keywords
Funding Information
- Balgrist Foundation (-)
This publication has 63 references indexed in Scilit:
- Shear Elastic Modulus on Patellar Tendon Captured from Supersonic Shear Imaging: Correlation with Tangent Traction Modulus Computed from Material Testing System and Test–Retest ReliabilityPLOS ONE, 2013
- Effect of Preconditioning and Stress Relaxation on Local Collagen Fiber Re-Alignment: Inhomogeneous Properties of Rat Supraspinatus TendonJournal of Biomechanical Engineering, 2012
- Immediate and short-term effects of exercise on tendon structure: biochemical, biomechanical and imaging responsesBritish Medical Bulletin, 2012
- Viscoelastic and Anisotropic Mechanical Properties of in vivo Muscle Tissue Assessed by Supersonic Shear ImagingUltrasound in Medicine & Biology, 2010
- Evidence against proteoglycan mediated collagen fibril load transmission and dynamic viscoelasticity in tendonMatrix Biology, 2009
- Isometric contractions reduce plantar flexor moment, Achilles tendon stiffness, and neuromuscular activity but remove the subsequent effects of stretchJournal of Applied Physiology, 2009
- Is tendon pathology a continuum? A pathology model to explain the clinical presentation of load-induced tendinopathyBritish Journal of Sports Medicine, 2008
- Chronic tendinopathy tissue pathology, pain mechanisms, and etiology with a special focus on inflammationScandinavian Journal of Medicine & Science in Sports, 2008
- When to use agreement versus reliability measuresJournal of Clinical Epidemiology, 2006
- Structure–function considerations of muscle–tendon junctionsComparative Biochemistry and Physiology Part A: Molecular & Integrative Physiology, 2002