Covalent Binding of Dexamethasone to Polyimide Improves Biocompatibility of Neural Implantable Devices
Authors:
- Giulia TurrinGTGiulia Turrin
- Jose CrugeirasJCJose Crugeiras
- Chiara BisquoliCBChiara Bisquoli
- Davide BarboniDBDavide Barboni
- Martina CataniMartina Catani
- Bruno Rodríguez‐MeanaBRBruno Rodríguez‐Meana
- Rita BoarettoRBRita Boaretto
- Michele AlbiciniMAMichele Albicini
- Stefano CaramoriSCStefano Caramori
- Claudio TrapellaCTClaudio Trapella
- Thomas StieglitzThomas Stieglitz
- Yara BaslanYBYara Baslan
Open Access
- 17 June 2025
- journal article
- Published by Wiley in Advanced Healthcare Materials
- Vol. 14 (21) , e2405004
Abstract
Neural implants are widely used in prosthetic applications to interact with the peripheral nervous system, but their long‐term functionality is compromised by foreign body reactions (FBR). Thanks to its high biocompatibility, polyimide poly (biphenyl dianhydride)‐ p ‐phenylenediamine (BPDA‐PDA) represents a suitable material to fabricate ultrathin and ultra‐flexible neural implants. This study explores the surface functionalization of BPDA‐PDA, the electrically inert component of the neural implant. The novelty of this approach relies on the fact that dexamethasone (DEX covalently bound to BPDA‐PDA, enabling its sustained release over a period of at least 9 weeks. In vitro assays demonstrate that this strategy reduce the production of pro‐inflammatory markers in macrophages. In addition, the biocompatibility of the functionalized material has been ensured by evaluating the viability of dorsal root ganglia (DRG) neurons. Furthermore, in vivo implantation of DEX functionalized BPDA‐PDA substrates shows a significant reduction in inflammatory cell infiltration and fibrotic capsule thickness formed around the devices. These findings suggest that local release of DEX from the electrically inactive scaffold of neural implants may enhance their long‐term stability and performance by mitigating the FBR.Keywords
Funding Information
- HORIZON EUROPE European Innovation Council (101099366)
This publication has 69 references indexed in Scilit:
- Engineered Graphene Material Improves the Performance of Intraneural Peripheral Nerve ElectrodesAdvanced Science, 2024
- A New Drug Delivery System Based on Tauroursodeoxycholic Acid and PEDOTChemistry – A European Journal, 2018
- Six‐Month Assessment of a Hand Prosthesis with Intraneural Tactile FeedbackAnnals of Neurology, 2018
- Dexamethasone Reduces the Foreign Body Reaction to Intraneural Electrode Implants in the Peripheral Nerve of the RatThe Anatomical Record, 2018
- Biochemically Controlled Release of Dexamethasone Covalently Bound to PEDOTChemistry – A European Journal, 2018
- Dexamethasone‐functionalized gels induce osteogenic differentiation of encapsulated hMSCsJournal of Biomedical Materials Research Part A, 2005
- Infrared Spectroscopy: Fundamentals and Applications2004
- Handbook of Infrared Spectroscopy of Ultrathin Films2003
- Morphologic and functional evaluation of peripheral nerve fibers regenerated through polyimide sieve electrodes over long‐term implantationJournal of Biomedical Materials Research, 2002
- Simple Method for the Esterification of Carboxylic AcidsAngewandte Chemie International Edition, 1978