Radio-frequency Tumor Ablation: Internally Cooled Electrode versus Saline-enhanced Technique in an Aggressive Rabbit Tumor Model
Authors:
- Thomas BoehmTBThomas Boehm
- Ansgar MalichAMAnsgar Malich
- S. Nahum GoldbergSGS. Nahum Goldberg
- Jürgen R. ReichenbachJRJürgen R. Reichenbach
- Ingrid HilgerIHIngrid Hilger
- Peter HauffPHPeter Hauff
- Michael ReinhardtMRMichael Reinhardt
- Marlies FleckMFMarlies Fleck
- Werner A. KaiserWKWerner A. Kaiser
- 1 March 2002
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 222 (3) , 805-813
Abstract
To compare two methods of radio-frequency (RF) ablation, saline enhancement technique and internally cooled electrodes, for the treatment of small breast cancers in an animal model--highly aggressive VX2 rabbit tumors surrounded by adipose tissue. Twenty-seven tumors were implanted into retroperitoneal fat of 14 New Zealand White rabbits. RF ablation was performed with ultrasonographic (US) guidance after tumors had grown to 15 mm. Fourteen tumors in seven animals were treated with internally cooled electrodes (30-mm-tip single electrode, 60 W, 10 min); 13 tumors in seven animals, with saline enhancement (0.5 mL/min of saline, 25-mm tip, 30 W, 10 min). Autopsy and histopathologic assessment were performed 3 weeks after therapy. Real-time US of RF ablation was not possible with either method because of obscuration by the increasing hyperechogenicity of the tumor and the surrounding adipose tissue. Equivalent efficacy was demonstrated with the two methods. Significantly greater complications were observed with the saline technique: Free retroperitoneal fluid was detected in one of seven animals with internally cooled electrodes and in all seven animals with saline enhancement (P <.01). Damage to remote structures such as the kidney, spine muscle, and skin was observed at autopsy in one of seven animals with internally cooled technique versus five of seven with saline enhancement (P <.01). Given a lower complication rate and similar treatment efficacy in an animal tumor model, internally cooled RF electrode may be advantageous to adjuvant saline infusion for the minimally invasive treatment of breast tumors.Keywords
This publication has 43 references indexed in Scilit:
- Tumor Ablation with Radio-frequency EnergyRadiology, 2000
- Hepatocellular Carcinoma: Radio-frequency Ablation of Medium and Large LesionsRadiology, 2000
- Minimally Invasive Treatment of Malignant Hepatic Tumors: At the Threshold of a Major BreakthroughRadioGraphics, 2000
- Small Hepatocellular Carcinoma: Treatment with Radio-frequency Ablation versus Ethanol InjectionRadiology, 1999
- Chorioamniotic separation after second-trimester genetic amniocentesis: importance and frequency.Radiology, 1998
- Percutaneous treatment of small hepatic tumors by an expandable RF needle electrode.American Journal of Roentgenology, 1998
- Hepatic metastases: percutaneous radio-frequency ablation with cooled-tip electrodes.Radiology, 1997
- A prospective randomized trial of interstitial radiofrequency therapy versus transurethral resection for the treatment of benign prostatic hyperplasiaBritish Journal of Urology, 1997
- Radiofrequency tissue ablation: Importance of local temperature along the electrode tip exposure in determining lesion shape and sizeAcademic Radiology, 1996
- Hepatic Ablation Using Radiofrequency ElectrocauteryInvestigative Radiology, 1990