Assessment of coronary artery remodelling by dual-source CT: a head-to-head comparison with intravascular ultrasound
Authors:
- Stephan AchenbachSAStephan Achenbach
- Tobias PfledererTPTobias Pflederer
- Annika SchuhbäckASAnnika Schuhbäck
- Werner G DanielWDWerner G Daniel
- Mohamed MarwanMMMohamed Marwan
Abstract
Background: While it is widely assumed that coronary CT angiography permits detection and quantification of ‘positive remodelling’ of coronary atherosclerotic lesions, there is a paucity of data comparing CT with established reference methods. Objective: To assess the accuracy of dual-source CT for detecting positive versus absent or negative coronary artery remodelling of coronary atherosclerotic lesions as compared with intravascular ultrasound (IVUS). Methods: The datasets were evaluated of 38 patients referred for invasive coronary angiography and in whom an IVUS study of one coronary vessel was performed. Coronary CT angiography was performed within 24 h before invasive coronary angiography. Using dual-source CT (Siemens Healthcare, Forchheim, Germany), a contrast-enhanced volume dataset was acquired (120 kV, 400 mA/rot, collimation 2×64×0.6 mm, 60–80 ml contrast agent, intravenous). IVUS was performed using a 40 MHz IVUS catheter (Atlantis, Boston Scientific Corporation, Natick, Massachusetts, USA) and motorised pullback at 0.5 mm/s. 48 corresponding non-calcified and partially calcified plaques within the coronary artery system were identified in both CT and IVUS using bifurcation points as fiducial markers. In CT datasets, multiplanar reconstructions orthogonal to the centre line of the coronary artery were rendered and cross-sectional vessel area was measured at the site of maximal narrowing as well as at a reference segment proximal to the lesion for each of the 48 plaques. The remodelling index (RI) was calculated by dividing the vessel area at the site of maximal narrowing by the area of the reference segment. Corresponding vessel areas and RIs were also determined in IVUS. Results: CT classified 41 plaques as positively remodelled (RI≥1.05) and seven as having either absent or negative remodelling (RI2 and 17± 5 mm2, respectively, versus 18±5 mm2 and 17±5 mm2 for IVUS (mean difference 1±2 mm2 and −0.2±1 mm2, p<0.0001 and 0.8, respectively). The mean RI in CT was significantly larger than in IVUS (1.2±0.2 vs 1.1±0.2, p0.9, p<0.0001) than for remodelling indices (r=0.7, p<0.0001) with Bland–Altman analysis showing a systematic overestimation of vessel areas and RI in CT. Interobserver agreement was moderate for CT and IVUS measurements. Receiver operating characteristic curve analysis showed that a RI of 1.1 in CT identified positively remodelled plaques in IVUS with a sensitivity of 83% and a specificity of 78% (area under the curve=0.8, 95% CI 0.7 to 1.0). Using the standard cut-off point of 1.05 to identify positively remodelled plaques in CT resulted in a sensitivity of 100%, and a specificity of 45%. Conclusion: Coronary CT angiography allows analysis of coronary artery remodelling. The degree of positive remodelling is typically overestimated by CT. A threshold of 1.1 for the RI may be optimal to classify plaques as ‘positively remodelled’ in coronary CT angiography.Keywords
This publication has 34 references indexed in Scilit:
- Characterization of culprit lesions in acute coronary syndromes using coronary dual-source CT angiographyAtherosclerosis, 2010
- Relationship between degree of remodeling and CT attenuation of plaque in coronary atherosclerotic lesions: An in-vivo analysis by multi-detector computed tomographyAtherosclerosis, 2008
- Assessment of Changes in Non-Calcified Atherosclerotic Plaque Volume in the Left Main and Left Anterior Descending Coronary Arteries over Time by 64-Slice Computed TomographyThe American Journal of Cardiology, 2008
- Diagnostic value of multislice computed tomography angiography in coronary artery disease: A meta-analysisEuropean Journal of Radiology, 2006
- Contrast-enhanced coronary artery visualization by dual-source computed tomography—Initial experienceEuropean Journal of Radiology, 2006
- Usefulness of Multidetector Row Spiral Computed Tomography With 64- × 0.6-mm Collimation and 330-ms Rotation for the Noninvasive Detection of Significant Coronary Artery StenosesThe American Journal of Cardiology, 2006
- Noncalcified and Calcified Coronary Plaque Detection by Contrast-Enhanced Multi-Detector Computed Tomography: A Study of Interobserver AgreementJACC, 2006
- First performance evaluation of a dual-source CT (DSCT) systemEuropean Radiology, 2005
- Comparison of measurement of cross-sectional coronary atherosclerotic plaque and vessel areas by 16-slice multidetector computed tomography versus intravascular ultrasoundThe American Journal of Cardiology, 2004
- assessment of coronary remodeling in stenotic and nonstenotic coronary atherosclerotic lesions by multidetector spiral computed tomographyJACC, 2004