Cerebrospinal fluid gusher in cochlear implantation
Authors:
- Ali EftekharianAEAli Eftekharian
- Maryam AmizadehMAMaryam Amizadeh
- 25 March 2014
- journal article
- Published by Taylor & Francis in Cochlear Implants International
- Vol. 15 (3) , 179-184
Abstract
To share our experience of cerebrospinal fluid (CSF) gusher in cochlear implantation. Demographic, radiological, and surgical results of patients with CSF gusher in 523 consecutive cochlear implant recipients including children and adults as well as our management technique were evaluated and a review of the literature has been included. Fifteen (2.87%) cases had CSF gusher. Two patients (13.3%) were adults with post-lingual hearing loss and the rest 12 (86.7%) were children with congenital hearing loss. Twelve patients (80%) had various types of inner ear malformation. Three patients (20%) had no predictable risk of CSF gusher from history or pre-operative imaging. In all patients, CSF gushers were controlled with our technique of packing the electrode entrance site with no additional measures. CSF gusher may occur with post-lingual hearing loss and in children with apparently unremarkable imaging and history. Thus, surgeons should always be ready to manage it. Management of CSF gusher can be mainly performed during the initial surgery by precise tight packing of the electrode entrance site. Furthermore, non-surgical or surgical measures are rarely required to stop a persistent leak. Our results show that our management technique may be recommended as well.Keywords
This publication has 14 references indexed in Scilit:
- Complicações em 550 cirurgias consecutivas de implante coclearBrazilian Journal of Otorhinolaryngology, 2015
- Influence of an Intraoperative Perilymph Gusher on Cochlear Implant Performance in Children With Labyrinthine MalformationsOtology & Neurotology, 2012
- Complicaciones y fallos de la implantación coclearActa Otorrinolaringológica Española, 2010
- Cochlear implant and inner ear malformationInternational Journal of Pediatric Otorhinolaryngology, 2008
- Cochlear Implantation in Children with Internal Ear MalformationsOtology & Neurotology, 2005
- CSF gusher in cochlear implantationCochlear Implants International, 2004
- Simple Method to Control a Cerebrospinal Fluid Gusher During Cochlear Implant SurgeryOtology & Neurotology, 2004
- Congenital Malformation of the Inner Ear and Pediatric Cochlear ImplantationOtology & Neurotology, 2004
- Implantation of the Malformed CochleaOtology & Neurotology, 2001
- Komplikationen der Cochlear Implant-Chirurgie bei Kindern und Erwachsenen1Laryngo-Rhino-Otologie, 1999