Atrioventricular Node Ablation in Langendorff-Perfused Porcine Hearts Using Carbon Ion Particle Therapy
Authors:
- H. Immo LehmannHLH. Immo Lehmann
- Daniel RichterDRDaniel Richter
- Hannah ProkeschHPHannah Prokesch
- Christian GraeffCGChristian Graeff
- Matthias PrallMPMatthias Prall
- Palma SimonielloPalma Simoniello
- Claudia FournierCFClaudia Fournier
- Julia BauerJBJulia Bauer
- Robert KaderkaRKRobert Kaderka
- Alexander WeymannAWAlexander Weymann
- Gábor SzabóGSGábor Szabó
- Karin SonnenbergKSKarin Sonnenberg
- 1 April 2015
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 8 (2) , 429-438
Abstract
Background—: Particle therapy, with heavy ions such as carbon-12 ( 12 C), delivered to arrhythmogenic locations of the heart could be a promising new means for catheter-free ablation. As a first investigation, we tested the feasibility of in vivo atrioventricular node ablation, in Langendorff-perfused porcine hearts, using a scanned 12C beam. Methods and Results—: Intact hearts were explanted from 4 (30–40 kg) pigs and were perfused in a Langendorff organ bath. Computed tomgraphic scans (1 mm voxel and slice spacing) were acquired and 12 C ion beam treatment planning (optimal accelerator energies, beam positions, and particle numbers) for atrioventricular node ablation was conducted. Orthogonal x-rays with matching of 4 implanted clips were used for positioning. Ten Gray treatment plans were repeatedly administered, using pencil beam scanning. After delivery, positron emission tomography-computed tomgraphic scans for detection of β + ( 11 C) activity were obtained. A 12 C beam with a full width at half maximum of 10 mm was delivered to the atrioventricular node. Delivery of 130 Gy caused disturbance of atrioventricular conduction with transition into complete heart block after 160 Gy. Positron emission computed tomgraphy demonstrated dose delivery into the intended area. Application did not induce arrhythmias. Macroscopic inspection did not reveal damage to myocardium. Immunostaining revealed strong γH2AX signals in the target region, whereas no γH2AX signals were detected in the unirradiated control heart. Conclusions—: This is the first report of the application of a 12 C beam for ablation of cardiac tissue to treat arrhythmias. Catheter-free ablation using 12C beams is feasible and merits exploration in intact animal studies as an energy source for arrhythmia elimination.Keywords
This publication has 33 references indexed in Scilit:
- Histopathological effects and evolution of transvenous -radiation applications in right and left atria: an animal studyEP Europace, 2011
- Motion in radiotherapy: particle therapyPhysics in Medicine & Biology, 2011
- Charged particles in radiation oncologyNature Reviews Clinical Oncology, 2009
- Pathological Effects of Pulmonary Vein β‐Radiation in a Swine ModelJournal of Cardiovascular Electrophysiology, 2006
- The impact of respiration on left atrial and pulmonary venous anatomy: Implications for image-guided interventionHeart Rhythm, 2005
- InteractiveThe Lancet Oncology, 2004
- β-Radiation for the Creation of Linear Lesions in the Canine AtriumCirculation, 2004
- Endothelial Apoptosis as the Primary Lesion Initiating Intestinal Radiation Damage in MiceScience, 2001
- Associated cardiac lesions in patients with radiation-induced complete heart blockInternational Journal of Cardiology, 1993
- Complete atrioventricular block following radiation therapy for malignant thymoma.Japanese Journal of Medicine, 1990