Mass Timber Envelopes in Passivhaus Buildings: Designing for Moisture Safety in Hot and Humid Australian Climates
Open Access
Abstract
The uptake of buildings employing cross-laminated timber (CLT) assemblies and designed to Passivhaus standard has accelerated internationally over the past two decades due to several factors including responses to the climate crisis by decarbonising the building stock. Structural CLT technology and the Passivhaus certification both show measurable benefits in reducing energy consumption, while contributing to durability and indoor comfort. However, there is a general lack of evidence to support a fast uptake of these technologies in Australia. This paper responds to the compelling need of providing quantitative data and adoption strategies; it explores their combined application as a potential pathway for climate-appropriate design of energy-efficient and durable mass timber envelope solutions for subtropical and tropical Australian climates. Hygrothermal risk assessments of interstitial condensation and mould growth of CLT wall assemblies inform best-practice design of mass timber buildings in hot and humid climates. This research found that the durability of mass timber buildings located in hot and humid climates may benefit from implementing the Passivhaus standard to manage interior conditions. The findings also suggested that climate-specific design of the wall assembly is critical for mass timber buildings, in conjunction with excellent stormwater management practices during construction and corrosion protection for metallic fasteners.Keywords
All Related Versions
Funding Information
- Advanced Solutions to Transform Tall Timber Buildings (IH150100030)
This publication has 27 references indexed in Scilit:
- Hygrothermal performance of cross-laminated timber wall assemblies: A stochastic approachBuilding and Environment, 2016
- Indoor air quality in passive and conventional new houses in SwedenBuilding and Environment, 2015
- Heating and cooling energy trends and drivers in buildingsRenewable and Sustainable Energy Reviews, 2015
- Hygrothermal performance of cross-laminated timber wall assemblies with built-in moisture: field measurements and simulationsBuilding and Environment, 2014
- Analysis and improvement of the representativeness of EN ISO 15927-4 reference years for building energy simulationJournal of Building Performance Simulation, 2013
- Low carbon construction systems using prefabricated engineered solid wood panels for urban infill to significantly reduce greenhouse gas emissionsSustainable Cities and Society, 2013
- Sensitivity of Hygrothermal Analysis to Uncertainty in Rain DataJournal of ASTM International, 2009
- CEPHEUS results: measurements and occupants’ satisfaction provide evidence for Passive Houses being an option for sustainable buildingEnergy Policy, 2006
- Development of the Typical and Design Weather Data for Asian LocationsJournal of Asian Architecture and Building Engineering, 2002
- Driving Rain on Building Envelopes— II. Representative Experimental Data for Driving Rain EstimationJournal of Thermal Envelope and Building Science, 2000