DEVELOPMENT OF A COLORIMETRIC SENSOR SYSTEM FOR RAPID OUT-OF-LABORATORY DETECTION OF ATRAZINE
Authors:
- Institute of Macromolecular Chemistry of the NAS of UkraineIUInstitute of Macromolecular Chemistry of the NAS of Ukraine
- Larysa GorbachLGLarysa Gorbach
- Tetiana SergeyevaTSTetiana Sergeyeva
- Оleksandr BrovkoОBОleksandr Brovko
- 1 January 2025
- journal article
- Published by National Academy of Sciences of Ukraine (Co. LTD Ukrinformnauka) (Publications) in Polymer journal
- Vol. 47 (3) , 111-117
Abstract
The aim of the work is to investigate the formation of binding sites in atrazine-selective molecularly imprinted polymers (MIPs) and to develop a colorimetric sensor system based on them for rapid out-of-laboratory detection of atrazine. The ability of MIPs to selectively bind the analyte compound (atrazine) and generate a colorimetric sensor response upon interaction with the appropriate reagent was combined. The features of the formation of binding sites in MIPs were studied by infrared spectroscopy. The infrared spectra were studied in detail, and the characteristic bands of the starting compounds were confirmed: the functional monomer of methacrylic acid (MAA), atrazine, and compositions based on them. The presence of intermolecular nonspecific interactions between atrazine and MAA molecules was proven. The low energy of these bonds (1-2 kcal/mol) facilitates the removal of atrazine during extraction, leading to the formation of a binding site. The molar ratio between atrazine and functional monomer in the initial monomer mixture was 1:2. The total content of atrazine in the polymer network was 5 wt.%. Studies have shown that MIP selectively binds to atrazine, generating a colorimetric sensory response. In other words, MIP films turn an intense purple color when interacting with the bromophenol blue/AgNO3 color reagent. The resulting colorimetric sensory system provides the highest sensory in comparison to structurally analogous analogues, including metribuzin, desmetrin, and simazine. Digital images of the colored samples were obtained using the camera of smartphone. The color intensity was assessed using the Color Grab software in the RGB color model. The detection limit of atrazine using the developed colorimetric sensor system is 0.9 μM, with an operational range of 0.9 - 2.3 μM.Keywords
This publication has 20 references indexed in Scilit:
- Pesticides and their degradation: A microbiological perspective2025
- Validation of a smartphone-compatible MIP-based sensor for bisphenol A determination in wastewater samplesAnalytical and Bioanalytical Chemistry, 2024
- Colorimetric test-systems for creatinine detection based on composite molecularly imprinted polymer membranesAnalytica Chimica Acta, 2013
- Review: Micro- and nanosized molecularly imprinted polymers for high-throughput analytical applicationsAnalytica Chimica Acta, 2009
- Porous molecularly imprinted polymer membranes and polymeric particlesAnalytica Chimica Acta, 2007
- Determination of pesticides in aqueous samples by solid-phase microextraction in-line coupled to gas chromatography—mass spectrometryJournal of the American Society for Mass Spectrometry, 1995
- Molecular Imprinting in Cross‐Linked Materials with the Aid of Molecular Templates— A Way towards Artificial AntibodiesAngewandte Chemie International Edition, 1995
- Solid-phase microextraction of nitrogen-containing herbicidesJournal of Chromatography A, 1995
- The Infra-red Spectra of Complex Molecules1975
- Methoden der organischen Chemie (Houben‐Weyl), herausgeg. von Eugen Müller. Band II, Analytische Methoden. G. Thieme, Stuttgart, 1953, 4. Aufl. XXII, 1070 S., 252 Abb., gebd. DM 139.–Angewandte Chemie, 1954