Comparable biocompatibility of Phisio- and Bioline-coated cardiopulmonary bypass circuits indicated by the inflammatory response
Authors:
- 1 January 2010
- journal article
- research article
- Published by SAGE Publications in Perfusion
- Vol. 25 (1) , 9-16
Abstract
Background: The biocompatibility of cardiopulmonary bypass surfaces has been improved by heparin and polymer surface modifications. The present study compared the effect of two such coatings on the inflammatory reactions after open heart surgery. Methods:Thirty patients undergoing elective heart surgery were randomly assigned to receive one of two types of coated circuits: Bioline (n=15) or phosphorylcholine (Phisio, n=15). The platelet and leukocyte counts, neutrophil activation (myeloperoxidase), complement activation (C3a and TCC), concentrations of lactate dehydrogenase, 27 cytokines (including interleukins, chemokines and growth factors), thrombin-antithrombin complexes, and the endothelial cell marker syndecan-1 were analyzed at five predetermined time points until 24 hrs post operatively. Results: Most measurements were comparable in both groups. However, myeloperoxidase was significantly higher in the Bioline group (p < 0.001). Postoperative lactate dehydrogenase concentrations were significantly higher in the Phisio group (p<0.01) and the maximal concentration of thrombin-antithrombin complexes 2 hours postoperatively tended to be higher in the Phisio group (p=0.08), consistent with a longer aortic cross-clamp and cardiopulmonary bypass time. Conclusions: The two circuits exhibited a comparable degree of in vivo biocompatibility.Keywords
This publication has 26 references indexed in Scilit:
- Blending in with the BodyJournal of Chemical Education, 2002
- Why do phospholipid polymers reduce protein adsorption?Journal of Biomedical Materials Research, 1998
- Depletion of Neutrophils by Filter During Aortocoronary Bypass Surgery Transiently Improves Postoperative Cardiorespiratory StatusChest, 1995
- Heparin-coated bypass circuits reduce pulmonary injuryThe Annals of Thoracic Surgery, 1993
- Heparin-coated circuits reduce the inflammatory response to cardiopulmonary bypassThe Annals of Thoracic Surgery, 1993
- Complement activation in septic baboons detected by neoepitope-specific assays for C3b/iC3b/C3c, C5a and the terminal C5b-9 complement complex (TCC)Clinical and Experimental Immunology, 1993
- Reduced Granulocyte Activation with a Heparin–Coated Device in an In Vitro Model of Cardiopulmonary BypassArtificial Organs, 1991
- The Effects of Complement Activation During Cardiopulmonary BypassAnnals of Surgery, 1988
- Quantification of the Terminal Complement Complex in Human Plasma by an Enzyme‐Linked Immunosorbent Assay Based on Monoclonal Antibodies against a Neoantigen of the ComplexScandinavian Journal of Immunology, 1985
- Complement Activation during Cardiopulmonary BypassNew England Journal of Medicine, 1981