Evaluation of Microbiologic and Hematologic Parameters and E-Selectin as Early Predictors for Outcome of Neonatal Sepsis
Open Access
- 1 August 2009
- journal article
- Published by Archives of Pathology and Laboratory Medicine in Archives of Pathology & Laboratory Medicine
- Vol. 133 (8) , 1291-1296
Abstract
Context. —Early diagnosis of neonatal sepsis is mandatory. Various markers are used to diagnose the condition. Objective. —To evaluate the diagnostic value of various clinical data and hematologic parameters, such as total leukocyte count, absolute neutrophil count, immature to total neutrophil ratio, and soluble E-selectin (sE-selectin) in identification and outcome of neonatal sepsis. Design. —Newborn infants with a clinical diagnosis of sepsis in the neonatal intensive care unit at Mansoura University Children's Hospital during the period between July 2007 and December 2007 were eligible for study. In addition, 30 healthy neonates were included in the study. Complete hematologic and microbiologic laboratory investigations were performed, and serum E-selectin was measured. Results. —Plasma sE-selectin levels were significantly higher ( P < .001) in infected infants (mean [SD], 156.9 [77.0] ng/mL) than in noninfected (mean [SD], 88.8 [47.1] ng/mL) and healthy infants (mean [SD], 8.67 [3.74] ng/ mL). Infants with gram-negative sepsis had higher sE-selectin levels than did those with gram-positive sepsis ( P = .04). C-reactive protein was the best laboratory test for diagnosis of neonatal sepsis, with an overall sensitivity and specificity of 86% and 97%, respectively. Performing sE-selectin with C-reactive protein or immature to total ratio tests increased the specificity, but reduced the sensitivity, of the tests for the determination of neonatal sepsis. Plasma sE-selectin levels were higher in nonsurvivors than in survivors ( P = .01) and were higher in those with hemodynamic dysfunction than in those without hemodynamic dysfunction ( P < .001). Conclusions. —We conclude that plasma sE-selectin levels are elevated in neonatal sepsis. Significant elevation was associated with gram-negative sepsis. Plasma sE-selectin had low diagnostic value when used alone or in combination with other tests; however, it can be used as a prognostic indicator for the outcome of neonatal sepsis.Keywords
This publication has 21 references indexed in Scilit:
- Epidemiology of neonatal infections: experience during and after hospitalizationThe Pediatric Infectious Disease Journal, 2003
- Role of cytokines (interleukin‐1β, 6, 8, tumour necrosis factor‐α, and soluble receptor of interleukin‐2) and C‐reactive protein in the diagnosis of neonatal sepsisActa Paediatrica, 2003
- Early diagnostic markers for neonatal sepsis Comparing C-reactive protein, interleukin-6, soluble tumour necrosis factor receptors and soluble adhesion moleculesJournal of Clinical Epidemiology, 2001
- Diagnosis of late onset neonatal sepsis with cytokines, adhesion molecule, and C-reactive protein in preterm very low birthweight infantsArchives of Disease in Childhood - Fetal and Neonatal Edition, 1997
- Infections in neonates delivered at term are associated with increased serum levels of ICAM‐1 and E‐selectinActa Paediatrica, 1997
- Comparison of C-reactive protein and white blood cell count with differential in neonates at risk for septicaemiaEuropean Journal of Pediatrics, 1995
- DIAGNOSTIC VALUE OF LEUKOCYTE INDICES IN LATE NEONATAL SEPSISThe Pediatric Infectious Disease Journal, 1994
- Complement activation in neonatal infection.Archives of Disease in Childhood, 1992
- The predictive value of CRP and I/T-ratio in neonatal infectionJournal of Perinatal Medicine, 1992
- Adhesion receptors of the immune systemNature, 1990