Abstract
It has been suggested that in infants born at term thoracic gas volume (TGV) may be more accurately estimated in a plethysmograph if end‐inspiratory (TGVI,) rather than end‐expiratory (TGVE,) occlusions are used. The aim of this study was to assess whether the timing of occlusion affected TGVI results in patients born very prematurely. Fifteen children with a median gestational age of 28 weeks (range 23–34) and postnatal age of 10 months (range 624) were studied. Measurements of TGV and airway resistance (Raw) were made in a whole body plethysmograph after sedation with chloral hydrate. End‐expiratory and end‐inspiratory occlusions were performed randomly in each subject. Overall, TGVI, was significantly lower than TGVE, (median, TGVI, 233 mL; range, 130–498. Median TGVI, 250 mL; range, 132–604; P < 0.05; 95% confidence intervals for the difference, 4–50 mL). In 13 infants, TGVI, was lower than TGVE, the remaining two patients did not differ significantly from the rest of the group and neither had neonatal chronic lung disease. In only five infants did TGVI, lie below the 95% confidence intervals of TGVE, however, two‐way analysis of variance with replicated measurements showed a significant difference between TGVI, and TGVE, (P < 0.05). The median Raw was 55 cmH2O/L/s (range, 36–71). A significant positive correlation was found between Raw and TGVE,‐TGVI, (r2 = 0.5, P < 0.01). We conclude that in children born very prematurely and with high Raw, occlusion at end‐expiration rather than end‐inspiration yields higher TGV results at follow‐up.Pediatr Pulmonol. 1994;18:295–298 © Wiley‐Liss, Inc.

This publication has 12 references indexed in Scilit: