Accelerometer output and its association with energy expenditure during manual wheelchair propulsion
Open Access
- 17 March 2015
- journal article
- research article
- Published by Springer Nature in Spinal Cord
- Vol. 54 (2) , 110-114
Abstract
Study design: This is an experimental design. Objectives: This study examined the association between rates of energy expenditure (that is, oxygen consumption (VO2)) and accelerometer counts (that is, vector magnitude (VM)) across a range of speeds during manual wheelchair propulsion on a motor-driven treadmill. Such an association allows for the generation of cutoff points for quantifying the time spent in moderate-to-vigorous physical activity (MVPA) during manual wheelchair propulsion. Setting: The study was conducted in the University Laboratory. Methods: Twenty-four manual wheelchair users completed a 6-min period of seated rest and three 6-min periods of manual wheelchair propulsion on a motor-driven wheelchair treadmill. The 6-min periods of wheelchair propulsion corresponded with three treadmill speeds (1.5, 3.0 and 4.5 mph) that elicited a range of physical activity intensities. Participants wore a portable metabolic unit and accelerometers on both wrists. Primary outcome measures included steady-state VO2 and VM, and the strength of association between VO2 and VM was based on the multiple correlation and squared multiple correlation coefficients from linear regression analyses. Results: Strong linear associations were established between VO2 and VM for the left (R=0.93±0.44; R2=0.87±0.19), right (R=0.95±0.37; R2=0.90±0.14) and combined (R=0.94±0.38; R2=0.88±0.15) accelerometers. The linear relationship between VO2 and VM for the left, right and combined wrists yielded cutoff points for MVPA of 3659 ±1302, 3630±1403 and 3644±1339 counts min−1, respectively. Conclusion: We provide cutoff points based on the linear association between energy expenditure and accelerometer counts for estimating time spent in MVPA during manual wheelchair propulsion using wrist-worn accelerometry. The similarity across wrist location permits flexibility in selecting a location for wrist accelerometry placement.Keywords
This publication has 14 references indexed in Scilit:
- Predicting Physical Activity Energy Expenditure in Manual Wheelchair UsersMedicine & Science in Sports & Exercise, 2014
- Validation of the use of Actigraph GT3X accelerometers to estimate energy expenditure in full time manual wheelchair users with spinal cord injurySpinal Cord, 2013
- Comparing handrim biomechanics for treadmill and overground wheelchair propulsionSpinal Cord, 2010
- Exercise Intervention Research on Persons with DisabilitiesAmerican Journal of Physical Medicine & Rehabilitation, 2010
- Calibration of Accelerometer Output for Ambulatory Adults With Multiple SclerosisArchives of Physical Medicine and Rehabilitation, 2009
- Accelerometer output and its association with energy expenditure in persons with multiple sclerosisJournal of Rehabilitation Research and Development, 2004
- A comparison of three methods for estimating height in the acutely ill elderly populationJournal of Human Nutrition and Dietetics, 2003
- The physical activity scale for individuals with physical disabilities: Development and evaluationArchives of Physical Medicine and Rehabilitation, 2002
- The level of accuracy and agreement in measures of FEO2, FECO2 and V̇E between the cosmed K4b2 portable, respiratory gas analysis system and a metabolic cartJournal of Science and Medicine in Sport, 2001
- Estimating Human Energy Expenditure Using An Accelerometer DeviceJournal of Clinical Engineering, 1984