Generation and visualization of four-dimensional MR angiography data using an undersampled 3-D projection trajectory
Authors:
- Jing LiuJLJing Liu
- M.J. RedmondMRM.J. Redmond
- E.K. BrodskyEBE.K. Brodsky
- A.L. AlexanderAAA.L. Alexander
- Aiming LuALAiming Lu
- F.J. ThorntonFTF.J. Thornton
- M.J. SchulteMSM.J. Schulte
- T.M. GristTGT.M. Grist
- J.G. PipeJPJ.G. Pipe
- W.F. BlockWBW.F. Block
- 30 January 2006
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 25 (2) , 148-157
Abstract
Time-resolved contrast-enhanced magnetic resonance (MR) angiography (CE-MRA) has gained in popularity relative to X-ray Digital Subtraction Angiography because it provides three-dimensional (3-D) spatial resolution and it is less invasive. We have previously presented methods that improve temporal resolution in CE-MRA while providing high spatial resolution by employing an undersampled 3-D projection (3D PR) trajectory. The increased coverage and isotropic resolution of the 3D PR acquisition simplify visualization of the vasculature from any perspective. We present a new algorithm to develop a set of time-resolved 3-D image volumes by preferentially weighting the 3D PR data according to its acquisition time. An iterative algorithm computes a series of density compensation functions for a regridding reconstruction, one for each time frame, that exploit the variable sampling density in 3D PR. The iterative weighting procedure simplifies the calculation of appropriate density compensation for arbitrary sampling patterns, which improve sampling efficiency and, thus, signal-to-noise ratio and contrast-to-noise ratio, since it is does not require a closed-form calculation based on geometry. Current medical workstations can display these large four-dimensional studies, however, interactive cine animation of the data is only possible at significantly degraded resolution. Therefore, we also present a method for interactive visualization using powerful graphics cards and distributed processing. Results from volunteer and patient studies demonstrate the advantages of dynamic imaging with high spatial resolution.Keywords
This publication has 28 references indexed in Scilit:
- 3D fluoroscopy with real‐time 3D non‐cartesian phased‐array contrast‐enhanced MRAMagnetic Resonance in Medicine, 2006
- Rapid fat‐suppressed isotropic steady‐state free precession imaging using true 3D multiple‐half‐echo projection reconstructionMagnetic Resonance in Medicine, 2005
- Time‐resolved contrast‐enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectoryMagnetic Resonance in Medicine, 2002
- Reduced aliasing artifacts using variable-densityk-space sampling trajectoriesMagnetic Resonance in Medicine, 2000
- Undersampled projection reconstruction applied to MR angiographyMagnetic Resonance in Medicine, 2000
- Reduced circular field‐of‐view imagingMagnetic Resonance in Medicine, 1998
- Effects of polar sampling in k‐spaceMagnetic Resonance in Medicine, 1996
- A Fast Sinc Function Gridding Algorithm for Fourier Inversion in Computer TomographyIEEE Transactions on Medical Imaging, 1985
- Experimental simulation evaluation of ECG‐gated heart scans with a small number of viewsMedical Physics, 1983
- True three-dimensional image reconstruction by nuclear magnetic resonance zeugmatographyPhysics in Medicine & Biology, 1981