Evaluation of Fumaric Acid and Maleic Acid as Internal Standards for NMR Analysis of Protein Precipitated Plasma, Serum, and Whole Blood
- 4 February 2021
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (6) , 3233-3240
Abstract
Significant advances have been made in unknown metabolite identification and expansion of the number of quantifiable metabolites in human plasma, serum, and whole blood using NMR spectroscopy. However, reliable quantitation of metabolites is still a challenge. A major bottleneck is the lack of a suitable internal standard that does not interact with the complex blood sample matrix and also does not overlap with metabolite peaks apart from exhibiting other favorable characteristics. With the goal of addressing this challenge, a comprehensive investigation of fumaric and maleic acids as potential internal standards was made along with a comparison with the conventional standards, TSP (trimethylsilylpropionic acid) and DSS (trimethylsilylpropanesulfonic acid). Both fumaric acid and maleic acid exhibited a surprisingly high performance with a quantitation error <1%, while the TSP and DSS caused an average error of up to 35% in plasma, serum, and whole blood. Further, the results indicate that while fumaric acid is a robust standard for all three biospecimens, maleic acid is suitable for only plasma and serum. Maleic acid is not suited for the analysis of whole blood due to its overlap with coenzyme peaks. These findings provide new opportunities for improved and accurate quantitation of metabolites in human plasma, serum, and whole blood using NMR spectroscopy. Moreover, the use of protein precipitation prior to NMR analysis mirrors the sample preparation commonly used for mass spectrometry based metabolomics, such that these findings further strengthen efforts to combine and compare NMR and MS based metabolite data of human plasma, serum, and whole blood for metabolomics based research.Keywords
Funding Information
- National Institutes of Health (R01 GM131491)
This publication has 41 references indexed in Scilit:
- Direct analysis of formate in human plasma, serum and whole blood by in-line coupling of microdialysis to capillary electrophoresis for rapid diagnosis of methanol poisoningAnalytica Chimica Acta, 2013
- Quantitative 1H NMR. Development and Potential of an Analytical Method: An UpdateJournal of Natural Products, 2012
- The Human Serum MetabolomePLOS ONE, 2011
- Survey and qualification of internal standards for quantification by 1H NMR spectroscopyJournal of Pharmaceutical and Biomedical Analysis, 2010
- Formic Acid, a Novel Metabolite of Chronic Ethanol Abuse, Causes Neurotoxicity, Which Is Prevented by Folic AcidAlcohol, Clinical and Experimental Research, 2007
- Progress toward automated metabolic profiling of human serum: Comparison of CPMG and gradient-filtered NMR analytical methodsJournal of Pharmaceutical and Biomedical Analysis, 2005
- Method Performance and Validation for Quantitative Analysis by 1H and 31P NMR Spectroscopy. Applications to Analytical Standards and Agricultural ChemicalsAnalytical Chemistry, 1998
- 1H NMR studies on protein binding of histidine, tyrosine and phenylalanine in blood plasmaNMR in Biomedicine, 1989
- NMR‐invisible lactate in blood plasmaFEBS Letters, 1988
- The signal-to-noise ratio of the nuclear magnetic resonance experimentJournal of Magnetic Resonance (1969), 1976