Pharmacokinetic and Pharmacodynamic Analysis of Alfaxalone Administered as a Bolus Intravenous Injection of Phaxan in a Phase 1 Randomized Trial
- 1 March 2020
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 130 (3) , 704-714
Abstract
BACKGROUND: Previous formulations of alfaxalone have shown it to be a fast-acting intravenous anesthetic with high therapeutic index. Alfaxalone has been reformulated for human use as Phaxan, an aqueous solution of 10 mg/mL of alfaxalone and 13% betadex. This study assessed the pharmacokinetic (PK) and pharmacodynamic (PD) characteristics of alfaxalone given as a bolus intravenous injection of this formulation to human male volunteers. METHODS: A dose of 0.5 mg/kg (0.42–0.55 mg/kg) of alfaxalone [mean (range)] was given by single intravenous bolus injection to 12 healthy subjects. Plasma alfaxalone concentrations and bispectral index (BIS) values were analyzed using an integrated pharmacokinetic–pharmacodynamic (PKPD) model using nonlinear mixed-effects models. Effect (BIS) was described using a sigmoidal fractional maximum effect (EMAX) model. All parameters were scaled using allometry and standardized to a 70-kg person using exponents of 0.75 for clearance parameters (CL, Q2, and Q3), 1.0 for volumes (V1, V2, and V3), and 0.25 for time-related parameters half-time keo (t 1/2keo). RESULTS: A 3-compartment model used to fit PK data with an additional compartment, linked by t 1/2keo to describe the effect compartment, yielded alfaxalone PK parameter estimates: CL: 1.08 L/min; 0.87–1.34 L/min (median; 95% confidence interval [CI]); central volume of distribution (V1): 0.99 L; 0.53–2.05 L (median; 95% CI); intercompartment CLs (Q2): 0.87 L/min; 0.32–1.71 L/min (median; 95% CI) and Q3: 0.46 L/min; 0.19–1.03 L/min (median; 95% CI); and peripheral volumes of distribution (V2): 6.36 L; 2.79–10.7 L (median; 95% CI) and V3: 19.1 L; 8.61–37.4 L (median; 95% CI). PD interrogation assumed a baseline BIS of 96, with an estimated EMAX: 0.94; 0.71–0.99 (median; 95% CI), a plasma concentration (Cp) for 50% effect (C50): 0.98 mg/L; 0.83–1.09 mg/L (median; 95% CI), and a Hill coefficient (γ): 12.1; 6.7–15 (median; 95% CI). The t 1/2keo was 8 minutes; 4.70–12.8 minutes (median; 95% CI). The mean time to a BIS 50 was 0.94 minutes (standard deviation [SD] = 0.2 minutes). CONCLUSIONS: After a single bolus intravenous injection, alfaxalone has a high plasma CL equal to hepatic blood flow as reported for earlier studies of bolus injections of a previous formulation of alfaxalone. The plasma levels associated with BIS values of t 1/2keo is relatively high, but the large Hill coefficient contributes to rapid onset and offset of action. This information can inform future studies of this formulation.Keywords
This publication has 34 references indexed in Scilit:
- Physiologic time: A hypothesisPhysics of Life Reviews, 2013
- An Evaluation of Using Population Pharmacokinetic Models to Estimate Pharmacodynamic Parameters for Propofol and Bispectral Index in ChildrenAnesthesiology, 2011
- Prediction-Corrected Visual Predictive Checks for Diagnosing Nonlinear Mixed-Effects ModelsThe AAPS Journal, 2011
- Postoperative painPediatric Anesthesia, 2008
- Extensions to the Visual Predictive Check to facilitate model performance evaluationJournal of Pharmacokinetics and Pharmacodynamics, 2008
- Investigating the pharmacodynamics of ketamine in childrenPediatric Anesthesia, 2007
- Propofol Pharmacokinetics and Pharmacodynamics Assessed from a Cremophor EL FormulationJournal of Pharmaceutical Sciences, 1997
- Pharmacodynamic modeling of the EEG effects of ketamine and its enantiomers in manJournal of Pharmacokinetics and Biopharmaceutics, 1987
- Bootstrap Methods for Standard Errors, Confidence Intervals, and Other Measures of Statistical AccuracyStatistical Science, 1986
- Seizure duration in unilateral electroconvulsive therapy A comparison of the anaesthetic agents etomidate and Althesin with methohexitoneActa Psychiatrica Scandinavica, 1984