Assessment of fluid responsiveness by inferior vena cava diameter variation in post‐pneumonectomy patients
Authors:
Open Access
- 18 October 2018
- journal article
- research article
- Published by Wiley in Echocardiography
- Vol. 35 (12) , 1922-1925
Abstract
Aim: First, the inferior vena cava dilatation index (DIVC) was measured by ultrasound, and then the reliability of DIVC as an indicator to predict volume responsiveness in patients undergoing mechanical ventilation after pneumonectomy was evaluated.Methods: Pulse indicator continuous cardiac output (Picco) as gold standard was performed to sedated mechanically ventilated post‐pneumonectomy patients in intensive care unit of Nanjing Thoracic Hospital from August 2014 to December 2016. Meanwhile, ultrasound measurement to inferior vena cava (IVC) diameter at the end inspiration (Dmax) and the end of expiration (Dmin) was performed. DIVC = (Dmax − Dmin)/Dmin. Above values were recorded at baseline and then after fluid resuscitation challenge (7 mL/kg hydroxyethyl starch). An increase in cardiac index of more than 15% was used as the standard for fluid responsiveness. Patients were divided into responsive group and non‐responsive group. A receiver operating characteristic (ROC) curve was then used to determine the sensitivity and specificity of DIVC in predicting fluid responsiveness after pneumonectomy.Results: Eighteen patients were enrolled. 10 patients were divided into responsive group and eight in non‐responsive group. DIVC in responsive group was significantly higher than in non‐responsive group (P < 0.01). By setting DIVC ≥ 15% as a measure of fluid responsiveness, sensitivity was 81.8% and specificity was 85.7%.Conclusion: DIVC is a reliable indicator of capacity responsiveness in mechanically ventilated post‐pneumonectomy patients.Keywords
Funding Information
- The Science and Technology Fund of Nanjing Municipal Commission of Health and Family Planning (YKK14133)
This publication has 16 references indexed in Scilit:
- Role of inferior vena cava diameter in assessment of volume status: a meta-analysisThe American Journal of Emergency Medicine, 2012
- Early complications after pneumonectomy: retrospective study of 168 patientsInteractive CardioVascular and Thoracic Surgery, 2010
- Inferior Vena Cava Distensibility as a Predictor of Fluid Responsiveness in Patients with Subarachnoid HemorrhageNeurocritical Care, 2010
- Continuous right ventricular end diastolic volume and right ventricular ejection fraction during liver transplantation: A multicenter studyLiver Transplantation, 2008
- Sonographic measurement of the inferior vena cava as a predictor of shock in trauma patientsEmergency Radiology, 2007
- Stroke Volume and Pulse Pressure Variation for Prediction of Fluid Responsiveness in Patients Under oing Off-Pump Coronary Artery Bypass GraftingChest, 2005
- Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patientsIntensive Care Medicine, 2004
- Preload and haemodynamic assessment during liver transplantation: a comparison between the pulmonary artery catheter and transpulmonary indicator dilution techniquesEuropean Journal of Anaesthesiology, 2002
- Preload and haemodynamic assessment during liver transplantation: a comparison between the pulmonary artery catheter and transpulmonary indicator dilution techniquesEuropean Journal of Anaesthesiology, 2002
- Perioperative fluid management for thoracic surgery: The puzzle of postpneumonectomy pulmonary edemaJournal of Cardiothoracic and Vascular Anesthesia, 1995