MODIFIED BLALOCK-TAUSSIG SHUNT IN INFANTS AND YOUNG-CHILDREN - CLINICAL AND CATHETERIZATION ASSESSMENT

Authors:
  • PKPP KARPAWICH
    PP KARPAWICH
  • CBCP BUSH
    CP BUSH
  • JAJ R ANTILLON
    J R ANTILLON
  • JAJJ AMATO
    JJ AMATO
  • MMML MARBEY
    ML MARBEY
  • KAKC AGARWAL
    KC AGARWAL

  • 1 January 1985
    • journal article
    • research article
    • Vol. 89  (2) , 275-279
    • PMID:3968910
Abstract
The effectiveness of 19 modified Blalock-Taussig shunts performed with expanded polytetrafluoroethylene was evaluated clinically and by cardiac catheterization with angiography 4-24 mo. after operation. Patients (15) underwent operation in infancy. Conduit diameters included 4 mm (9 cases), 5 mm (8 cases) and 6 mm (2 cases) sizes. Of the 4 mm conduits failed (2) after 1 yr following implantation. The remaining 17 shunts (89%) remained widely patent. In patients with patent shunts, the O2 saturation values were significantly improved from the preoperative values. Children (2) demonstrated associated subclavian artery occlusion distal to the graft anastomosis. There were no deaths. Children (13) underwent more complete-elective cardiac repair 5-24 mo. later. Although the modified Blalock-Taussig procedure is an effective short-term alternative to the classic Blalock-Taussig shunt, the effectiveness of the 4 mm diameter conduit may be limited without postoperative anticoagulant therapy.