Estimation of Line Parameters, Tap Changer Ratios, and Systematic Measurement Errors Based on Synchronized Measurements and a General Model of Tap-Changing Transformers
Open Access
- 5 September 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Instrumentation and Measurement
- Vol. 1, 1-11
Abstract
A primary requirement for the transmission system operator is an accurate knowledge of grid parameters. Moreover, the availability of effective and accurate monitoring tools allows the proper operation of power transmission grids. However, in spite of the now widespread possibility of having monitoring systems based on synchronized measurements, the monitoring applications can be affected not only by the inevitable uncertainty sources but also by the simplified or incomplete modeling of the network components. For this reason, the impact on power system monitoring and control applications of tap-changing transformer models is a key point. In this scenario, this article presents a method to estimate simultaneously line parameters, tap changer ratios, and systematic measurement errors associated with the instrument transformers. The method exploits a flexible model of the tap-changing transformer based on a parameter representing the ratio between the two winding impedances of the transformer. The proposal is based also on the suitable modeling of the measurement chain and on the constraints introduced by the equations of involved transmissions lines and transformers. The validation has been carried out by means of tests performed on the IEEE 14 Bus Test Case.Keywords
Funding Information
- Fondazione di Sardegna for the Research Project “IQSS, Information Quality Aware and Secure Sensor Networks for Smart Cities,” year 2020
This publication has 23 references indexed in Scilit:
- A PMU-based Technique for the Simultaneous Estimation of Systematic Measurement Errors, Line Parameters and Tap Changer Ratio2021
- The modeling of tap-changing transformers andP-Vbuses using the sensitivity impedance matrixInternational Transactions on Electrical Energy Systems, 2020
- On the Consistency of Tap-Changing Transformer Models in Power System Studies2020
- Mechanical Fault Diagnostics of Power Transformer On-Load Tap Changers Using Dynamic Time WarpingIEEE Transactions on Instrumentation and Measurement, 2019
- IEEE/IEC International Standard - Measuring relays and protection equipment - Part 118-1: Synchrophasor for power systems - Measurements2018
- Uncertainty Bounds of Transmission Line Parameters Estimated From Synchronized MeasurementsIEEE Transactions on Instrumentation and Measurement, 2018
- Utilization of PMU Measurements for Three-Phase Line Parameter Estimation in Power SystemsIEEE Transactions on Instrumentation and Measurement, 2018
- Improved model for tap‐changing transformerIET Generation, Transmission & Distribution, 2013
- Load Tap Change Transformers: A Modeling ReminderIEEE Power Engineering Review, 2001
- Test systems for harmonics modeling and simulationIEEE Transactions on Power Delivery, 1999