Prospective randomized trial of high versus low vacuum drainage after axillary lymphadenectomy
Authors:
- 1 July 1995
- journal article
- clinical trial
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 82 (7) , 931-932
Abstract
A randomized prospective trial was performed to assess the effect of low versus high vacuum drainage after axillary lymphadenectomy. The mean(s.e.m.) volume of seroma evacuated with a low vacuum system was 386(26) ml (n = 38) compared with 537(43) ml with a high vacuum system (n = 40) (P< 0.005). Low vacuum drains were removed earlier than high vacuum drains (P = 0.02). Seroma production after removal of the drains was not significantly different. The use of low vacuum drains after axillary dissection can reduce hospital stay.Keywords
This publication has 5 references indexed in Scilit:
- Axillary LymphadenectomyArchives of Surgery, 1990
- Early Versus Delayed Shoulder Motion Following Axillary DissectionAnnals of Surgery, 1981
- A comparison between disposable and non-disposable suction drainage units: A report of a controlled trialBritish Journal of Surgery, 1979
- A comparison between suction and corrugated drainage after simple mastectomy: A report of a controlled trialBritish Journal of Surgery, 1976
- A controlled trial of closed wound suction drainage in radical mastectomyBritish Journal of Surgery, 1973