Abstract
In 2003, four grain silos, each 104 ft (32 m) in. diameter and 100 ft (31 m) tall, were constructed at a waterfront storage facility in Mobile, Alabama, to replace a cold storage facility that had been demolished. Foundation plans for the replacement silos included auger-cast piles to support the perimeter steel shell walls on a concrete ring, auger-cast piles to support the buried conveyor tunnel used to unload grain and a soil-supported interior floating floor slab (isolated from the perimeter ring and conveyor tunnel) to support grain loads on the order of 5,000 psf (240 kN/m2). During the initial loading of Silo #1, as filling neared capacity, the structure suddenly shifted and began to lean toward the south. Large cracks appeared in the concrete foundation system and structural steel beams located at the top of the silo twisted. Because grain storage silos were in short supply in the aftermath of hurricane Katrina, the owners of the storage facility hired the authors to conduct a unique, full scale test loading program, by placing Silos #2, #3 and #4 into production. Using available historical data, along with supplemental data gathered specifically for settlement monitoring, the authors developed a full scale test loading protocol designed to help the owner temporarily store grain, while simultaneously evaluating foundation performance. This paper discusses geotechnical and structural assumptions used in design of the silo foundations. Then, using data collected from full scale loading of the silo foundations to impending failure, the authors describe lessons learned by comparing expectations of foundation performance to measured performance.