Transdermal Electrochemical Monitoring of Glucose via High‐Density Silicon Microneedle Array Patch
- 4 March 2021
- journal article
- research article
- Published by Wiley in Advanced Functional Materials
- Vol. 32 (3) , 2009850
Abstract
Current technology for blood glucose level monitoring is mainly based on the invasive finger‐prick extraction of a small drop of blood using a lancet and measured via a handheld glucometer, which is not conducive to continuous measurements. Interstitial fluid (ISF) is gaining attention as an alternative biofluid. Its biochemical composition is very similar to that of blood and it can be monitored in a continuous manner via minimally invasive methods that cause no pain and minimize any risk of infection. Herein, a microneedle array (MNA) based transdermal sensing system for the pain free monitoring of ISF glucose is presented. High‐density silicon microneedles (≈9500 microneedles cm−2) are used to prepare a three‐electrode patch for the electrochemical monitoring of glucose. The MNA glucose patch shows very good selectivity when tested in artificial ISF, with a sensitivity of 0.1622 µA mm−1 cm−2 and a detection limit of 0.66 mm. In vivo application of the microneedle array in mice shows that the ISF glucose concentrations obtained with the MNA sensor gave very good correlation with the blood glucose levels determined with a commercial glucometer. This microneedle‐based sensing system hence provides an alternative transdermal diagnostic tool to the invasive existing techniques.Keywords
Funding Information
- Australian National Fabrication Facility
This publication has 47 references indexed in Scilit:
- Microneedles for transdermal diagnostics: Recent advances and new horizonsBiomaterials, 2020
- Skin in the diagnostics game: Wearable biosensor nano- and microsystems for medical diagnosticsNano Today, 2020
- A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweatNature Biotechnology, 2019
- Accessing analytes in biofluids for peripheral biochemical monitoringNature Biotechnology, 2019
- Wearable sweat sensorsNature Electronics, 2018
- Proteomic Characterization of Dermal Interstitial Fluid Extracted Using a Novel Microneedle-Assisted TechniqueJournal of Proteome Research, 2017
- Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysisNature, 2016
- Anatomy, Physiology, Histology, and Immunohistochemistry of Human Skin2016
- The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring SystemDiabetes Technology & Therapeutics, 2015
- The thickness of the epidermisBritish Journal of Dermatology, 1973