Glucose oxidase-loaded liposomes forin situamplified signal of electrochemical immunoassay on a handheld pH meter
- 8 December 2018
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in New Journal of Chemistry
- Vol. 43 (3) , 1372-1379
Abstract
Methods based on a pH meter have been developed for immunoassays, but most involve low sensitivity and weakly detectable signals, and thus are unsuitable for routine use. Herein, a simple and portable electrochemical immunoassay was designed for sensitive screening of a disease-related biomarker, neuron-specific enolase (NSE), by using glucose oxidase-loaded liposomes (GOx-LS) for signal amplification. Initially, a sandwiched immunoreaction was performed on rabbit anti-human monoclonal NSE antibody-coated microplate with polyclonal rabbit anti-human NSE antibody-labeled GOx-LS. Thereafter, the GOx-LS accompanying the immunocomplex could oxidize glucose into gluconic acid and hydrogen peroxide, thus resulting in the pH change of the detection solution, which could be registered on a handheld pH meter. Relative to GOx-labeling, use of GOx-LS could amplify the signal of the electrochemical immunosensing platform. Under optimum conditions, the GOx-LS-based immunoassay exhibited good pH responses toward target NSE within the dynamic linear range of 0.01–100 ng mL−1 with a detection limit of 8.9 pg mL−1. The coefficients of variation for the reproducibility and precision of this method were less than 7.9% and 12.7% for the single-batch and different-batch identification, respectively. High specificity and acceptable stability were acquired for determining target NSE using this method. For the detection of human serum specimens, well-matched results were provided between pH-based immunoassay and commercial Electrochemiluminescent Automatic Analyzer.Keywords
Funding Information
- National Natural Science Foundation of China (61705177, 61335012, 61727823, 61575156, 61775178, 61505159)
- China Postdoctoral Science Foundation (2017M613107, 2015M572570)
This publication has 39 references indexed in Scilit:
- Electrochemical immunosensor for N6-methyladenosine detection in human cell lines based on biotin-streptavidin system and silver-SiO2 signal amplificationBiosensors and Bioelectronics, 2017
- Recent Advances in Electrochemical ImmunosensorsAnalytical Chemistry, 2016
- Inflammation-induced reversible switch of the neuron-specific enolase promoter from Purkinje neurons to Bergmann gliaScientific Reports, 2016
- Neuron specific enolase: a promising therapeutic target in acute spinal cord injuryMetabolic Brain Disease, 2016
- Enhanced ELISA using a handheld pH meter and enzyme-coated microparticles for the portable, sensitive detection of proteinsChemical Communications, 2015
- Sandwich-type immunosensors and immunoassays exploiting nanostructure labels: A reviewAnalytica Chimica Acta, 2013
- Magnetic Core−Shell Fe3O4@Ag Nanoparticles Coated Carbon Paste Interface for Studies of Carcinoembryonic Antigen in Clinical ImmunoassayThe Journal of Physical Chemistry B, 2006
- Microbial biosensorsBiosensors and Bioelectronics, 2001
- Neuron-specific enolaseTrends in Neurosciences, 1982
- The construction of inexpensive digital pH metersJournal of Chemical Education, 1982