Base Pressure Control with Annular Ribs

Authors:

Abstract
This paper presents the experimental results on the flow characteristics of a suddenly expanded flow from subsonic and sonic nozzles. The present study employs passive control in the form of a rib to investigate the base pressure for the enlarged duct. The nozzle pressure ratio (NPR) was varied from 1 to 7. The length to diameter ratio of the enlarged duct was varied from 0.5D to 6D. The aspect ratio of the rib was varied from 0.45 to 1.25. The experimental results showed that the base pressure was strongly influenced by the aspect ratio of the rib at a given L/D ratio. For L/D = 0.5, NPR 3 was found to be critical as seen from the increasing trend in base pressure with NPR. The present study explicitly reveals that, the base pressure in a suddenly expanded axi-symmetric duct can be controlled by employing a rib of appropriate aspect ratio as a passive control device.