Effects of modular ion-funnel technology onto analysis of breath VOCs by means of real-time mass spectrometry
Open Access
- 13 August 2020
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 412 (26) , 7131-7140
Abstract
Proton transfer reaction time-of-flight mass spectrometry (PTR-ToF-MS) is a powerful tool for real-time monitoring of trace concentrations of volatile organic compounds (VOCs). The sensitivity of PTR-ToF-MS also depends on the ability to effectively focus and transmit ions from the relatively high-pressure drift tube (DT) to the low-pressure mass analyzer. In the present study, a modular ion-funnel (IF) is placed adjacent to the DT of a PTR-ToF-MS instrument to improve the ion-focusing. IF consists of a series of electrodes with gradually decreasing orifice diameters. Radio frequency (RF) voltage and direct current (DC) electric field are then applied to the electrodes to get the ions focused. We investigated the effect of the RF voltage and DC field on the sensitivity of a pattern of VOCs including hydrocarbons, alcohols, aldehydes, ketones, and aromatic compounds. In a proof-of-concept study, the instrument operating both as normal DT (DC-mode) and at optimal IF conditions (RF-mode) was applied for the breath analysis of 21 healthy human subjects. For the range of investigated VOCs, an improvement of one order of magnitude in sensitivity was observed in RF-mode compared with DC-mode. Limits of detection could be improved by a factor of 2–4 in RF-mode compared with DC-mode. Operating the instrument in RF-mode allowed the detection of more compounds in the exhaled air compared with DC-mode. Incorporation of the IF considerably improved the performance of PTR-ToF-MS allowing the real-time monitoring of a larger number of potential breath biomarkers.Keywords
Funding Information
- H2020 Marie Skłodowska-Curie Actions (IMPACT/674911)
This publication has 29 references indexed in Scilit:
- Increased Sensitivity in Proton Transfer Reaction Mass Spectrometry by Incorporation of a Radio Frequency Ion FunnelAnalytical Chemistry, 2012
- High resolution PTR-TOF: Quantification and formula confirmation of VOC in real timeJournal of the American Society for Mass Spectrometry, 2010
- A high resolution and high sensitivity proton-transfer-reaction time-of-flight mass spectrometer (PTR-TOF-MS)International Journal of Mass Spectrometry, 2009
- An online ultra-high sensitivity Proton-transfer-reaction mass-spectrometer combined with switchable reagent ion capability (PTR+SRI−MS)International Journal of Mass Spectrometry, 2009
- The ion funnel: Theory, implementations, and applicationsMass Spectrometry Reviews, 2009
- Proton-Transfer Reaction Mass SpectrometryChemical Reviews, 2009
- Measurements of volatile organic compounds in the earth's atmosphere using proton‐transfer‐reaction mass spectrometryMass Spectrometry Reviews, 2006
- Demonstration of Proton-Transfer Reaction Time-of-Flight Mass Spectrometry for Real-Time Analysis of Trace Volatile Organic CompoundsAnalytical Chemistry, 2004
- Validation of proton transfer reaction‐mass spectrometry (PTR‐MS) measurements of gas‐phase organic compounds in the atmosphere during the New England Air Quality Study (NEAQS) in 2002Journal of Geophysical Research: Atmospheres, 2003
- Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb levelInternational Journal of Mass Spectrometry and Ion Processes, 1995