An integrated microfluidic chip for synchronous drug loading, separation and detection of plasma exosomes
- 14 May 2025
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (13) , 3185-3196
Abstract
A microfluidic chip integrating a 3D macroporous scaffold and magnetoresponsive electrode achieves exosome isolation, electrochemical detection, and doxorubicin loading, offering a seamless platform for analysis and therapeutic delivery.Keywords
Funding Information
- National Natural Science Foundation of China (22274120)
- National Key Research and Development Program of China (2022YFA1104802)
This publication has 46 references indexed in Scilit:
- Boron Clusters Escort Doxorubicin Squashing Into Exosomes and Overcome Drug ResistanceAdvanced Science, 2024
- Boron Cluster Anions Dissolve En Masse in Lipids Causing Membrane Expansion and ThinningAngewandte Chemie International Edition, 2024
- Size and Polarizability of Boron Cluster Carriers Modulate Chaotropic Membrane TransportAngewandte Chemie International Edition, 2024
- Microfluidic Biochips for Single‐Cell Isolation and Single‐Cell Analysis of Multiomics and ExosomesAdvanced Science, 2024
- Exosome‐mediated PROTACs delivery to target viral infectionsDrug Development Research, 2023
- A High‐Throughput Nanofluidic Device for Exosome Nanoporation to Develop Cargo Delivery VehiclesSmall, 2021
- Spatial Control of Probiotic Bacteria in the Gastrointestinal Tract Assisted by Magnetic ParticlesAdvanced Materials, 2021
- Engineered Extracellular Vesicles for Cancer TherapyAdvanced Materials, 2021
- Progress in Microfluidics‐Based Exosome Separation and Detection Technologies for Diagnostic ApplicationsSmall, 2019
- Isolation and Profiling of Circulating Tumor‐Associated Exosomes Using Extracellular Vesicular Lipid–Protein Binding Affinity Based Microfluidic DeviceSmall, 2019